4-55
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 4 Error Messages
EID-6329 Protection/AIS action cannot be both set to squelch. Refer to the error message text.
EID-6330 The node failed to restart the Pseudo IOS CLI service on the
selected port. Try using another unreserved port that is not
being used within the 1024 - 65535 range.
Refer to the error message text.
EID-6331 That port is already in use.
Also note that the Pseudo IOS port may not be changed if any
Pseudo IOS connections are currently open.
Refer to the error message text.
WID-6332 All previously configured IPv6 destinations will become
unreachable if IPv6 mode is disabled. It is recommended that
you remove all IPv6 related provisioning before disabling IPv6
mode.
Do you want to continue?
Refer to the warning message text.
WID-6333 The NE default {0} not available in the selected NE Defaults
Tree.
Refer to the warning message text.
WID-6334 Could not find the NE default {0}. Refer to the warning message text.
WID-6335 CTC was unable to create a new Target account. Refer to the warning message text.
WID-6336 Changing the card to EFEC mode will cause the ports 1 and 2
to be disabled.
Do you want to continue?
Refer to the warning message text.
WID-6337 CE-MR-10/CE-MR-6 card does not validate the Ethernet FCS
when traffic is received from optical side. This can result in
errored frames from optical side being forwarded to the peer
device via front ports. It would be left to the peer device to
detect the errors and discard the frames.
It is suggested to enable the FCS option on both ends of the
circuit. The GFP FCS will be used to discard errored frames.
The discarded frames will be accounted under the performance
pane for the POS port.
Refer to the warning message text.
WID-6338 Ingress COS setting is not compatible with QinQ mode. Refer to the warning message text.
WID-6339 Some circuits may become partial as part of this upgrade and
would need to be reconfigured.
Refer to the warning message text.
WID-6340 One or more QinQ rules have not been deleted because they are
not related to the current circuit.
Refer to the warning message text.
WID-6341 The Functional view on {0} is disabled. Refer to the warning message text.
WID-6342 Changing the {0} settings might be traffic affecting.
Do you want to continue?
Refer to the warning message text.
WID-6343 The selected file name is too long.
File names (including the full path) must be less than 254
characters.Please enter a valid file name.
Refer to the warning message text.
EID-6344 It is detected a shelf mismatch condition. Refer to the error message text.
EID-6345 The line termination is invalid. Refer to the error message text.
EID-6346 The overhead is not supported. Refer to the error message text.
Table 4-1 Error Messages (continued)
Error/Warning
ID Error/Warning Message Description
Komentarze do niniejszej Instrukcji