Cisco 15310-MA Instrukcja Naprawy Strona 231

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 230
2-101
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
2.7.149 LOS (BITS)
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: BITS
The LOS (BITS) alarm indicates that the 15310-CL-CTX or CTX2500 card has an LOS from the BITS
timing source. The LOS (BITS-N) means the BITS clock or the connection to it failed.
Clear the LOS (BITS) Alarm
Step 1 Verify the wiring connection from the BITS clock pin fields on the ONS 15310-CL or ONS 15310-MA
to the timing source.
Caution Always use the supplied electrostatic discharge wristband when working with a powered ONS 15310-CL
or ONS 15310-MA.
Step 2 If wiring is good, verify that the BITS clock is operating properly.
Step 3 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447) in order to report a Service-Affecting (SA)
problem.
2.7.150 LOS (DS1)
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Object: DS1
An LOS (DS1) alarm for a DS-1 port on a 15310-CL-CTX, DS1-28/DS3-EC1-3, or DS1-84/DS3-EC1-3
card occurs when the port on the port is in service but no signal is being received. The cabling might not
be correctly connected to the port, or the line could have no signal.
Note When the ONS 15310-MA raises an LOF (DS1) or LOS (DS1) alarm, a path protection switch will
occur, but a PDI-P alarm will not be generated due to hardware limitations.
Clear the LOS (DS1) Alarm
Step 1 Verify that the cable is properly connected and attached to the correct port. For more information about
cable connections and terminations, refer to the “Install Hardware” chapter in the Cisco ONS 15310-CL
and Cisco ONS 15310-MA Procedure Guide.
Caution Always use the supplied electrostatic discharge wristband when working with a powered ONS 15310-CL
or ONS 15310-MA.
Step 2 Consult site records to determine whether the port raising the alarm has been assigned.
Przeglądanie stron 230
1 2 ... 226 227 228 229 230 231 232 233 234 235 236 ... 379 380

Komentarze do niniejszej Instrukcji

Brak uwag