1-76
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 1 General Troubleshooting
CTC Operation Troubleshooting
Note CTC will notify you if an older version JRE is running on your Microsoft Windows PC or UNIX
workstation.
Launch CTC to Correct the Core Version Build
Step 1 Exit the current CTC session and completely close the browser.
Step 2 Start the browser.
Step 3 Type the node IP address of the node that reported the alarm. This can be the original IP address you
logged in with or an IP address other than the original.
Step 4 Log into CTC. The browser downloads the JAR file from CTC.
1.10.8 Different CTC Releases Do Not Recognize Each Other
Symptom Different CTC releases on the same network do not recognize each other.
Table 1-15 describes the potential cause of the symptom and the solution.
Launch CTC to Correct the Core Version Build
Step 1 Exit the current CTC session and completely close the browser.
Step 2 Start the browser.
Step 3 In the Node Name field, type the ONS 15310-CL or ONS 15310-MA IP address of the node that reported
the alarm. This can be the original IP address you logged on with or an IP address other than the original.
Table 1-15 Different CTC Releases Do Not Recognize Each Other
Possible Problem Solution
The software loaded on
the connecting
workstation and the
software on the
ONS 15310-CL or
ONS 15310-MA are
incompatible.
This occurs when the port software is upgraded but the Microsoft Windows
PC has not yet upgraded the compatible CTC JAR file. It also occurs on login
nodes with compatible software that encounter other nodes in the network
that have a newer software version. See the “Launch CTC to Correct the Core
Version Build” procedure on page 1-76.
Note Remember to always log into the ONS node with the latest CTC core
version first. If you initially log into an ONS node running a CTC
core version of 2.2 or earlier and then attempt to log into another
ONS node in the network running a later CTC core version, the
earlier version node does not recognize the new node.
Note This situation is often accompanied by the INCOMPATIBLE-SW
alarm.
Przeglądanie stron 111
1 2 ... 107 108 109 110 111 112 113 114 115 116 117 ... 379 380

Komentarze do niniejszej Instrukcji

Brak uwag

Clear-Com Türsprechanlagen Benutzerhandbücher

Beginnend mit T

Klicken Sie auf den Alphabet unten, um zur vollständigen Liste der Modelle zu gelangen, die mit diesem Buchstaben beginnen

Modelle Dokumententyp
TEMPEST 2400
Bedienungsanleitung   Clear-Com_Tempest - John S. Hyatt & Associates, Inc., 16 Seiten
Bedienungsanleitung   Clear Com Tempest 2400 CP-242 brochure, 8 Seiten
Spezifikationen   Clear-Com TEMPEST 2400 Specifications, 100 Seiten
Tempest2400
Bedienungsanleitung   Tempest®2400 - AV, 12 Seiten