
2-34
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
Note This condition is only reported if the path protection is set up for revertive switching.
Clear the AUTOSW-SFBER Condition
Step 1 Complete the “Clear the SF-P Condition” procedure on page 2-135.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.30 AUTOSW-UNEQ (STSMON)
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: STSMON
The Automatic Path Protection Switch Caused by Unequipped condition indicates that an UNEQ alarm
caused automatic UPSR protection switching to occur (see the “UNEQ-P” condition on page 2-151). If
the UPSR is configured for revertive switching, it reverts to the working path after the fault clears.
Note This condition is only reported if the path protection is set up for revertive switching.
Clear the AUTOSW-UNEQ (STSMON) Condition
Step 1 Complete the “Clear the UNEQ-P Alarm” procedure on page 2-151.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.31 AUTOSW-UNEQ (VT-MON)
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: VT-MON
The automatic path protection switch caused by an unequipped condition (VT-MON) indicates that the
“UNEQ-V” alarm on page 2-153 alarm caused automatic UPSR protection switching to occur. If the
UPSR is configured for revertive switching, it reverts to the working path after the fault clears.
Note This condition is only reported if the path protection is set up for revertive switching.
Komentarze do niniejszej Instrukcji