EID-3016 The subnet address is invalid. Refer to the error message text.
EID-3017 The subnet address already exists. Refer to the error message text.
EID-3019 The internal subnet address is incomplete. Enter the complete internal subnet address.
EID-3020 The subnet address cannot be the same for both TSC cards.
The requested action is not allowed.
A node’s internal subnet must be different
from one another as each TSC is on separate
ethernet buses, isolated by broadcast
domains.
EID-3021 An error occurred while retrieving the diagnostics:
{0}
Refer to the error message text.
EID-3022 The requested action is not allowed. The requested action is not allowed.
EID-3023 The low order cross-connect mode could not be retrieved. Refer to the error message text.
EID-3024 The {0} cross-connect mode could not be switched.
Please verify that the type and/or number of circuits
provisioned does not exceed the criterion for switching modes.
CTC cannot switch the cross-connect mode
for the specified item, as the type or the
number of circuits does not match with the
criterion for switching modes.
EID-3025 An error occurred while retrieving thresholds. There was an error retrieving the
thresholds.
EID-3026 The send DoNotUse attribute cannot be modified. You cannot modify the Send DoNotUse
field.
EID-3027 The SyncMsg attribute cannot be modified. You cannot modify the SyncMsg field.
EID-3028 The port type cannot be changed. You cannot change the port type.
EID-3029 Unable to switch to the byte because an overhead change is
present on this byte of the port.
Refer to the error message text.
EID-3031 An error occurred while hard-resetting the card. There was an error while resetting card
hardware.
EID-3032 An error occurred while resetting the card. There was an error while resetting the card.
EID-3033 The lamp test is not supported on this shelf. Refer to the error message text.
EID-3035 The cross-connect diagnostics cannot be performed Refer to the error message text.
EID-3036 The cross-connect diagnostics test is not supported on this
shelf.
The cross-connect diagnostics test is not
supported on this shelf.
EID-3039 An error occurred while changing the card type. There was an error while changing the card.
EID-3040 The card type is invalid. The selected card type is invalid.
EID-3041 An error occurred while applying changes. CTC is unable to create a protection group.
Check if the protect port supports circuits, a
timing reference, SONET SDCC,
orderwire, or a test access point.
EID-3042 The flow control low value must be less than the flow control
high value for all ports in the card.
Refer to the error message text.
EID-3046 The flow control watermark value must be between {0} and
{1}, inclusive.
The flow control watermark value must be
between the two specified values.