2-113
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
2.7.166 LPBKTERMINAL (OCN)
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: OCN
A Loopback Terminal condition for an OC-N port occurs when a software terminal (inward) loopback
is active for an OC-3 or OC-12 port on the 15310-CL-CTX or CTX2500 card.
Note OC-N terminal loopbacks do not typically return an AIS.
Note Performing a loopback on an in-service circuit is Service-Affecting (SA). If you did not perform a
lockout or Force switch to protect traffic, the LPBKTERMINAL condition can also be accompanied by
a more serious alarm such as LOS.
For information about troubleshooting electrical circuits with loopbacks, refer to the “1.2 Identify
Points of Failure on an Electrical Circuit Path” section on page 1-3; for optical circuits, refer to the
“1.3 Identify Points of Failure on an OC-N Circuit Path” section on page 1-16. Terminal loopbacks are
described in the “1.1.2 Terminal Loopback” section on page 1-3.
Clear the LPBKTERMINAL (OCN) Condition
Step 1 Complete the “Clear an OC-N Port Facility or Terminal Loopback Circuit” procedure on page 2-165.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.167 LWBATVG
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Object: PWR
The Low Voltage Battery alarm occurs in a –48 VDC environment for an ONS 15310-CL when a battery
lead input voltage falls below the low power threshold. This threshold has a preset value of –44 VDC
and is not user-provisionable. The alarm remains raised until the voltage remains above the threshold for
120 seconds. (For information about changing this threshold, refer to the “Turn Up Node” chapter in the
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.)
Clear the LWBATVG Alarm
Step 1 The problem is external to the ONS 15310-CL or ONS 15310-MA. Troubleshoot the power source
supplying the battery leads.