Type the Attack Gain Change Rate. It is in units of -
0.00212 dB per millisecond. By default, the AGCR value is
400 units.
Type the Decay Gain Change Rate. It is in units of -
0.00212 dB per millisecond. By default, the DGCR value is
4 units.
Type the target amplitude.
Select the check box to activate automatic gain control.
This optimizes the voice data to facilitate a wide dynamic
range, typically encountered when a voice logger is
connected close to a PBX or analog phone.
Select the check box to enable Light Masking. It needs to
be enabled if Light ID does not come in a sequence of 1,
2, 3 etc., in sub reason of the Light events. This is an
advanced setting.
Light Mask for stop event
Select the check box to enable light masking for stop
event only.
Select the check box to enable hook sync. If this option is
enabled, the recording starts by OFF HOOK event and
stops by ON HOOK event. Normally HOOK
synchronization can be disabled and Event
Synchronization used instead of this, as Event
Synchronization is more precise and handles many
combinations of start and stop.
Select the check box to enable dial digits cloning. If this
option is enabled and there is no DTMF, the display
information is extracted to get the dial digits.
Select the check box to disable primary and secondary
channel mixing. This option is used for some of the E1
installations with the IPC systems.
Select the check box to enable all call details. If this
option is enabled, both caller ID and dial digits
information will be displayed.
Select the check box to capture the PRI extensions.