Available system uptime = 2 days, 2 hours, 39 minutes
Switchovers system experienced = 0
Standby failures = 0
Last switchover reason = none
Hardware Mode = Duplex
Configured Redundancy Mode = Stateful Switchover
Operating Redundancy Mode = Stateful Switchover
Maintenance Mode = Disabled
Communications = Up
Current Processor Information :
Active Location = slot 1
Current Software state = ACTIVE
Uptime in current state = 2 days, 2 hours, 39 minutes
Image Version = Cisco Internetwork Operating System Software
IOS (tm) Catalyst 4000 L3 Switch Software (cat4000−I5S−M), Version 12.2(20)EWA(3
.92), CISCO INTERNAL USE ONLY ENHANCED PRODUCTION VERSION
Copyright (c) 1986−2004 by cisco Systems, Inc.
Compiled Wed 14−Jul−04 04:42 by esi
BOOT = bootflash:cat4000−i5s−mz.122_20_EWA_392,1
Configuration register = 0x2002
Peer Processor Information :
Standby Location = slot 2
Current Software state = STANDBY HOT
Uptime in current state = 2 days, 2 hours, 39 minutes
Image Version = Cisco Internetwork Operating System Software
IOS (tm) Catalyst 4000 L3 Switch Software (cat4000−I5S−M), Version 12.2(20)EWA(3
.92), CISCO INTERNAL USE ONLY ENHANCED PRODUCTION VERSION
Copyright (c) 1986−2004 by cisco Systems, Inc.
Compiled Wed 14−Jul−04 0
BOOT = bootflash:cat4000−i5s−mz.122_20_EWA_392,1
Configuration register = 0x2002
show redundancy statesThis can be used to verify whether the redundant supervisor is in redundant
mode as expected.
Switch#show redundancy states
my state = 13 −ACTIVE
peer state = 8 −STANDBY HOT
Mode = Duplex
Unit = Primary
Unit ID = 2
Redundancy Mode (Operational) = Stateful Switchover
Redundancy Mode (Configured) = Stateful Switchover
Split Mode = Disabled
Manual Swact = Enabled
Communications = Up
client count = 21
client_notification_TMR = 240000 milliseconds
keep_alive TMR = 9000 milliseconds
keep_alive count = 0
keep_alive threshold = 18
RF debug mask = 0x0
•
Manual Switchover Commands
Manual switchover commands can be used to perform manual switchover from the active supervisor to the
redundant supervisor engine.
The redundancy force−switchover command launches the switchover only if the state of the redundant
supervisor engine is Standby Hot. If the state is not Standby Hot, the command does not process. Issue the
redundancy force−switchover command, rather than the reload command, to initiate a switchover. The