1-9
Cisco 7600 Series Internet Router Module Installation Guide
78-12798-07
Chapter 1 Product Overview
Supervisor Engines
Table 1-3 Supervisor Engines 1A and 2 LEDs
LED Color Description
STATUS
Orange The module is booting or running diagnostics (normal initialization
sequence).
An overtemperature condition has occurred. (A minor threshold has
been exceeded during environmental monitoring.)
Green All diagnostics pass; the module is operational (normal initialization
sequence).
Red Diagnostic test failed; the module is not operational. (The fault occurred
during the initialization sequence.)
An overtemperature condition has occurred. (A major threshold has
been exceeded during environmental monitoring.)
SYSTEM
1
Orange The power supply or power supply fan failed.
Incompatible power supplies are installed.
The redundant clock failed.
One VTT
2
module has failed or the VTT module temperature minor
threshold has been exceeded
3
.
Red Two VTT modules failed or the VTT module temperature major
threshold has been exceeded
3
.
The temperature of the supervisor engine major threshold has been
exceeded.
Green All chassis environmental monitors are reporting OK.
ACTIVE
Orange The supervisor engine is in standby mode.
Green The supervisor engine is operational and active.
PWR MGMT
1
Orange Sufficient power is not available for all modules.
Green Sufficient power is available for all modules.
SWITCH LOAD
If the system is operational, the switch load meter indicates (as an
approximate percentage) the current traffic load over the backplane.
PCMCIA
The PCMCIA LED is lit when no PCMCIA card is in the slot and goes
off when you insert a card.
Komentarze do niniejszej Instrukcji