Cisco UCS C24 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Serwery Cisco UCS C24. Cisco UCS C24 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Rack-Mount Server

CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.1 NOVEMBER 2, 2012 WWW.CISCO.COMCisco UCS C24 M3High-Density Small Fo

Strona 2 - CONTENTS

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server10CONFIGURING the SERVERSTEP 2 SELECT CPU(s)The standard CPU features are: Intel Xeon E5-2400 seri

Strona 3 - OVERVIEW

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER11STEP 3 SELECT MEMORYThe standard memory features are: DIMMs— Clock speed:

Strona 4 - DETAILED VIEWS

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server12CONFIGURING the SERVERSelect DIMMsSelect the memory configuration. The available memory DIMMs are

Strona 5 - Chassis Rear View

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER13(2) 2-CPU configuration with memory mirroring: Select 2 or 4 DIMMs per CPU

Strona 6

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server14CONFIGURING the SERVERSTEP 4 SELECT RAID CONFIGURATIONFor the 24-drive version of the server, the

Strona 7

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER15Approved Configurations For 24-drive backplane with expander systems— Sele

Strona 8

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server16CONFIGURING the SERVER— If you select a plug-in RAID controller from Table 5, you can select addi

Strona 9 - STEP 1 VERIFY SERVER SKU

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER17STEP 5 SELECT HARD DISK DRIVES (HDDs)The standard disk drive features are:

Strona 10 - STEP 2 SELECT CPU(s)

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server18CONFIGURING the SERVERApproved Configurations(1) LSI MegaRAID 9265CV-8i (with data cache and Supe

Strona 11 - STEP 3 SELECT MEMORY

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER19STEP 6 SELECT PCIe OPTION CARD(s)The standard PCIe card offerings are: Con

Strona 12 - CONFIGURING the SERVER

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server2CONTENTS OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 13

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server20CONFIGURING the SERVERApproved Configurations(1) No RAID controller plug-in card If you did not

Strona 14

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER21STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIESCopper twinax cables and SFP

Strona 15

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server22CONFIGURING the SERVERChoose Optional SFP ModulesOptical Cisco SFP+ modules are listed in Table 9

Strona 16

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER23Figure 5 Network Card Connections

Strona 17 - ■ there are no drives, or

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server24CONFIGURING the SERVERSTEP 8 SELECT AC POWER CORD(s)Using Table 10, select the appropriate AC pow

Strona 18

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER25CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug, AustraliaSFS-250V-10A-CN Pow

Strona 19 - Notes . .

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server26CONFIGURING the SERVERCAB-9K10A-SW Power Cord, 250VAC 10A MP232 Plug, SwitzerlandCAB-9K10A-UK Pow

Strona 20

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER27STEP 9 ORDER POWER SUPPLIESThe C24 M3 server accommodates two power supplie

Strona 21

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server28CONFIGURING the SERVERSTEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARMThe reversible cable

Strona 22

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER29STEP 11 ORDER A TRUSTED PLATFORM MODULETrusted Platform Module (TPM) is a c

Strona 23

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerOVERVIEW3 OVERVIEWThe Cisco® UCS C24 M3 Rack Server combines economics and a density-optimized feat

Strona 24

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server30CONFIGURING the SERVERSTEP 12 ORDER OPTIONAL USB 2.0 DRIVESYou may order one or two optional USB

Strona 25

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER31STEP 13 SELECT OPERATING SYSTEMSeveral operating systems are available from

Strona 26

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server32CONFIGURING the SERVERVMWare ServerVMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Ye

Strona 27 - STEP 9 ORDER POWER SUPPLIES

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER33STEP 14 SELECT OPERATING SYSTEM MEDIA KITSelect the optional operating syst

Strona 28

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server34CONFIGURING the SERVERSTEP 15 SELECT OPTIONAL VALUE-ADDED SOFTWAREYou can select from a variety o

Strona 29

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER35STEP 16 SELECT SERVICE and SUPPORT LEVELA variety of service options are av

Strona 30

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server36CONFIGURING the SERVERworld. As a part of this service, Cisco will assist in issues involving thi

Strona 31

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER37Mission Critical Support ServiceThis service delivers personalized technica

Strona 32

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server38CONFIGURING the SERVERabout Cisco Mission Critical Support Service, please visit Data Center Tech

Strona 33

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerOPTIONAL STEP - ORDER RACK(s)39OPTIONAL STEP - ORDER RACK(s)The optional R42610 rack is available f

Strona 34

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server4DETAILED VIEWSDETAILED VIEWSChassis Front ViewFigure 2 shows the Cisco UCS C24 M3 High-Density SFF

Strona 35

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server40OPTIONAL STEP - ORDER PDUOPTIONAL STEP - ORDER PDUAn optional power distribution unit (PDU) is av

Strona 36

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL41SUPPLEMENTAL MATERIALCHASSISAn internal view of the C24 M3 chassis with the

Strona 37

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server42SUPPLEMENTAL MATERIALCPUs and DIMMsPhysical LayoutEach CPU has three DIMM channels: CPU1 has cha

Strona 38 - Manager

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL43Memory Population RulesWhen considering the memory configuration of your ser

Strona 39 - OPTIONAL STEP - ORDER RACK(s)

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server44SUPPLEMENTAL MATERIALRecommended Memory PopulationThis section explains the recommended DIMM popu

Strona 40 - OPTIONAL STEP - ORDER PDU

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL45Supported DIMM PopulationsThe supported DIMM populations are listed in Table

Strona 41 - SUPPLEMENTAL MATERIAL

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server46SUPPLEMENTAL MATERIALLow-Voltage DIMM ConsiderationsThe C24 M3 server can be ordered with low-vol

Strona 42 - CPUs and DIMMs

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL47RACKSThe Cisco R42610 rack (see Figure 8) is certified for Cisco UCS install

Strona 43 - Memory Population Rules

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server48SUPPLEMENTAL MATERIALFigure 8 Cisco R42610 RackFront view - door closed Front view - door open

Strona 44 - Recommended Memory Population

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL49PDUsCisco RP Series Power Distribution Units (PDUs) offer power distribution

Strona 45 - Supported DIMM Populations

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerDETAILED VIEWS5Chassis Rear ViewFigure 3 shows the external features of the rear panel.Figure 3 C

Strona 46

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server50SUPPLEMENTAL MATERIALMotherboard USB PortThe C24 M3 SFF motherboard has one general-purpose USB s

Strona 47

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL51LED IndicatorsThe server contains LED indicators on the front and rear panel

Strona 48 - Figure 8 Cisco R42610 Rack

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server52SUPPLEMENTAL MATERIALHard Drive Activity Off There is no hard drive in the hard drive sled (no ac

Strona 49

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL53Rear PanelFigure 12 shows the rear panel LEDs.Figure 12 Rear Panel LEDsUni

Strona 50 - Motherboard USB Port

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server54SUPPLEMENTAL MATERIALSee Table 27 for the functions of the rear panel LEDs.Table 27 Rear Panel L

Strona 51 - LED Indicators

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerTECHNICAL SPECIFICATIONS55TECHNICAL SPECIFICATIONSDimensions and WeightPower SpecificationsThe gene

Strona 52

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server56TECHNICAL SPECIFICATIONSThe general power specifications for the C24 M3 SFF server 650 W power su

Strona 53 - Rear Panel

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerTECHNICAL SPECIFICATIONS57Environmental SpecificationsThe power specifications for the C24 M3 serve

Strona 54

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server58TECHNICAL SPECIFICATIONSCompliance RequirementsThe regulatory compliance requirements for C-Serie

Strona 55 - TECHNICAL SPECIFICATIONS

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server6BASE SERVER STANDARD CAPABILITIES and FEATURESBASE SERVER STANDARD CAPABILITIES and FEATURESTab le

Strona 56

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerBASE SERVER STANDARD CAPABILITIES and FEATURES7External Storage Devices A 16 GB USB 2.0 drive (if

Strona 57 - Environmental Specifications

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server8CONFIGURING the SERVERCONFIGURING the SERVERFollow these steps to configure the Cisco UCS C24 M3 H

Strona 58 - Compliance Requirements

Cisco UCS C24 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER9STEP 1 VERIFY SERVER SKUThe 24-drive version of the server has a SAS expande

Komentarze do niniejszej Instrukcji

Brak uwag