STEP: 5 Select the RAID controller option. (optional)
The default option is SATA RAID 0/1 controller (integrated on motherboard). Only four SATA drives are supported
with the default option. SAS drives are not supported with the integrated RAID controller. If SAS drives are ordered,
more than four drives or greater RAID functionality is required, one of the following options must be chosen.
If you order SAS drives and/or SATA advanced RAID options are required, one of the following options must be
chosen.
●
LSI 1064E Controller-Based Mezzanine Card R2X0-ML002
◦ Used on the mezzanine slot inside the UCS C200 Server
◦ Supports up to 4 SAS or SATA hard disk drives
◦ No battery back-up available
◦ Factory-configured RAID options
◦ RAID 0 (Striping) R2XX-RAID0
Requires a minimum of one hard drive
◦ RAID 1 (Mirroring) R2XX-RAID1
Requires exactly two hard drives with the same size, speed and capacity
●
LSI 6G MegaRAID 9261-8i PCIe Card R2XX-PL003
◦ Takes up one of five available PCIe slots
◦ Supports up to sixteen SAS and/or SATA drives
◦ Includes 512 MB of Write Cache
◦ Battery Back-Up Option Available
◦ Factory-configured RAID options:
◦ RAID 0 (Striping) R2XX-RAID0
Requires a minimum of one hard drive
◦ RAID 1 (Mirroring) R2XX-RAID1
Requires exactly two hard drives with the same size, speed and capacity
◦ RAID 5 R2XX-RAID5
Requires a minimum of three HDDs, all with identical speed and capacity
◦ RAID 6 R2XX-RAID6
Requires a minimum of four HDDs, all with identical speed and capacity
◦ RAID 10 R2XX-RAID10
Requires a minimum of four HDDs, all with identical speed and capacity
Contents: Overview Detailed Views Base Unit Features Configuring Memory HDD