CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV C.11 SEPTEMBER 10, 2014 WWW.CISCO.COMSpec SheetCisco UCS B200 M3Blade S
Cisco UCS B200 M3 Blade Server10CONFIGURING the SERVERSupported Configurations(1) One-CPU Configuration Choose one CPU from any one of the rows of Ta
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER11— The connectivity options are:• VIC 1340 or 1240 installed in VIC 1340/1240 slot and no adapter
Cisco UCS B200 M3 Blade Server12CONFIGURING the SERVERSTEP 3 CHOOSE MEMORYThe standard memory features are: DIMMs— Clock speed: 1866, 1600, or 1333 M
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER13Choose DIMMs and Memory MirroringSelect the memory configuration and whether or not you want the
Cisco UCS B200 M3 Blade Server14CONFIGURING the SERVERSupported Configurations(1) B200 M3 configured with 1 CPU without memory mirroring Select from
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER15(3) B200 M3 configured with 2 CPUs without memory mirroring: Select from 1 to 12 DIMMs per CPU
Cisco UCS B200 M3 Blade Server16CONFIGURING the SERVERCaveats System speed is dependent on how many DIMMs are populated per channel. See Table 7 for
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER17— DIMM choice— DIMM population (how many DIMMs per channel are populated)— BIOS setting. For the
Cisco UCS B200 M3 Blade Server18CONFIGURING the SERVERSTEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES (OPTIONAL)The UCS B200 M3 can be ordered wi
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER19Supported Configurations(1) 1-Drive System Select one of the drives listed in Table 8. (1) 2-Dr
Cisco UCS B200 M3 Blade Server2OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3DETAILED VIEWS
Cisco UCS B200 M3 Blade Server20CONFIGURING the SERVERSTEP 5 CHOOSE ADAPTERSThe adapter offerings are: Cisco Virtual Interface Cards (VICs)Cisco deve
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER21Supported Configurations(1) B200 M3 configured with 1 CPUFor a B200 M3 configured with 1 CPU, th
Cisco UCS B200 M3 Blade Server22CONFIGURING the SERVER(2) B200 M3 configured with 2 CPUsFor a B200 M3 configured with 2 CPUs, the supported configurat
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER23Also see NEBS Compliance on page 49 for more information.To help ensure that your operating syst
Cisco UCS B200 M3 Blade Server24CONFIGURING the SERVERSTEP 6 ORDER A TRUSTED PLATFORM MODULETrusted Platform Module (TPM) is a computer chip (microcon
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER25STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDSDual SDHC flash card sockets are provided
Cisco UCS B200 M3 Blade Server26CONFIGURING the SERVERSTEP 8 ORDER OPTIONAL INTERNAL USB 2.0 DRIVEYou may order one optional internal USB 2.0 drive. T
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER27STEP 9 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARESeveral operating systems and value-added
Cisco UCS B200 M3 Blade Server28CONFIGURING the SERVERRed Hat Enterprise LinuxRHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs RequiredRHEL-2S-1G-3A RHEL/
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER29VMware 5VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support RqdVMW-VS5-STD
Cisco UCS B200 M3 Blade ServerOVERVIEW3OVERVIEWDelivering performance, versatility and density without compromise, the Cisco UCS B200 M3 Blade Server
Cisco UCS B200 M3 Blade Server30CONFIGURING the SERVERSTEP 10 CHOOSE OPERATING SYSTEM MEDIA KITChoose the optional operating system media listed in Ta
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER31STEP 11 CHOOSE SERVICE and SUPPORT LEVELA variety of service options are available, as described
Cisco UCS B200 M3 Blade Server32CONFIGURING the SERVERUnified Computing Warranty Plus ServiceFor faster parts replacement than is provided with the st
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER33Partner Support Service for UCS provides hardware and software support, including triage support
Cisco UCS B200 M3 Blade Server34CONFIGURING the SERVERYou can choose a service listed in Table 21.Unified Computing Drive Retention ServiceWith the Ci
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER35For more service and support information, see the following URL:http://www.cisco.com/en/US/servi
Cisco UCS B200 M3 Blade Server36CONFIGURING the SERVERORDER OPTIONAL KVM LOCAL I/O CABLE*The KVM local I/O cable ships with every UCS 5100 Series blad
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL37SUPPLEMENTAL MATERIALSystem BoardA top view of the UCS B200 M3 system board is shown in Figure 5.
Cisco UCS B200 M3 Blade Server38SUPPLEMENTAL MATERIALCPUs and DIMMsPhysical LayoutMemory is organized as shown in Figure 6.Figure 6 UCS B200 M3 Memo
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL39— Bank 1 - E1, F1, G1, and H1 (black DIMM slots)— Bank 2 - E2, F2, G2, and H2 (white DIMM slots)T
Cisco UCS B200 M3 Blade Server4DETAILED VIEWSDETAILED VIEWSBlade Server Front ViewFigure 2 is a detailed front view of the Cisco UCS B200 M3 Blade Ser
Cisco UCS B200 M3 Blade Server40SUPPLEMENTAL MATERIALDIMM Population Rules When considering the memory configuration of your server, you should take i
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL41DIMM Population OrderPopulate the DIMMs for a CPU according to Table 25.Table 25 DIMM Populatio
Cisco UCS B200 M3 Blade Server42SUPPLEMENTAL MATERIALRecommended Memory ConfigurationThis section explains the recommended DIMM population order rules
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL43192 GB4x8 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB10663244x16 GB 2x16 GB — 4x16 GB 2x16 GB — 1866 12
Cisco UCS B200 M3 Blade Server44SUPPLEMENTAL MATERIAL96 GB4x4 GB 4x4 GB 4x4 GB 4x4 GB 4x4 GB 4x4 GB 1066 244x8 GB 2x8 GB — 4x8 GB 2x8 GB — 1600 123x16
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL45Additional DIMM PopulationsThe list in Table 28 is not a complete list of all supported DIMM popu
Cisco UCS B200 M3 Blade Server46SUPPLEMENTAL MATERIALUpgrade and Servicing-Related PartsThis section lists the upgrade and servicing-related parts you
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL47Adding an Additional CPU (with CPU heat sink)All Cisco UCS two CPU socket-capable servers can be
Cisco UCS B200 M3 Blade Server48SUPPLEMENTAL MATERIALAir Baffle Replacement KitAir baffles are designed to direct airflow through the server to mainta
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL49NEBS ComplianceWhen configured with the specific set of components shown in Table 30, the UCS B20
Cisco UCS B200 M3 Blade ServerBASE SERVER STANDARD CAPABILITIES and FEATURES5BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 lists the capabilit
Cisco UCS B200 M3 Blade Server50SUPPLEMENTAL MATERIALNetwork ConnectivityThis section explains how the UCS B200 M3 server connects to Fabric Interconn
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL51The network adapter options are: Cisco VIC 1340 or adapter. This adapter plugs into the VIC 1340
Cisco UCS B200 M3 Blade Server52SUPPLEMENTAL MATERIALFigure 9 VIC 1340/1240 Port ConnectivityThe number of ports available at the mezzanine adapter
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL53 Emulex or QLogic I/O adapters—Emulex M73KR-E— QLogic M73KR-Q Cisco Storage Accelerator adapter
Cisco UCS B200 M3 Blade Server54SUPPLEMENTAL MATERIALFigure 10 Option 1 - VIC 1340/1240 to UCS 2208XP Fabric Extender (no mezzanine adapter)
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL55In Figure 11, two ports from the VIC 1340/1240 are channeled to 2208XP Fabric Extender A and two
Cisco UCS B200 M3 Blade Server56SUPPLEMENTAL MATERIALFigure 12 Option 1 - VIC 1340/1240 to UCS 2204XP Fabric Extender (no mezzanine adapter)In Figur
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL57Connectivity using the Cisco UCS 2104XP Fabric ExtenderThe option shown in Figure 14 demonstrates
Cisco UCS B200 M3 Blade Server58SUPPLEMENTAL MATERIALB200 M3 Configured with 2 CPUsConnectivity using the Cisco UCS 2208XP Fabric ExtenderThe Cisco UC
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL59In Figure 16, two ports from the VIC 1340/1240 are channeled to 2208XP Fabric Extender A and two
Cisco UCS B200 M3 Blade Server6BASE SERVER STANDARD CAPABILITIES and FEATURESVideo The Cisco Integrated Management Controller (CIMC) provides video:
Cisco UCS B200 M3 Blade Server60SUPPLEMENTAL MATERIALIn Figure 18, two ports from the VIC 1340/1240are channeled to 2208XP Fabric Extender A and two a
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL61Connectivity using the Cisco UCS 2204XP Fabric ExtenderThe Cisco UCS 2204XP is a second-generatio
Cisco UCS B200 M3 Blade Server62SUPPLEMENTAL MATERIALIn Figure 21, one port from the VIC 1340/1240 is channeled to 2204XP Fabric Extender A and one is
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL63In Figure 23, one port from the VIC 1340/1240 is channeled to 2204XP Fabric Extender A and one is
Cisco UCS B200 M3 Blade Server64SUPPLEMENTAL MATERIALConnectivity using the Cisco UCS 2104XP Fabric ExtenderThe options shown in Figure 25 and Figure
Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL65Figure 26 Option 2 - VIC 1340/1240 to UCS 2104XP Fabric Extender (Cisco Storage Accelerator ins
Cisco UCS B200 M3 Blade Server66TECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONSDimensions and WeightPower SpecificationsFor configuration-specific po
Cisco UCS B200 M3 Blade ServerTECHNICAL SPECIFICATIONS67
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER7CONFIGURING the SERVERFollow these steps to configure the Cisco UCS B200 M3 Blade Server: STEP 1
Cisco UCS B200 M3 Blade Server8CONFIGURING the SERVERSTEP 1 VERIFY SERVER SKUVerify the product ID (PID) of the server as shown in Table 2.The base Ci
Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER9STEP 2 CHOOSE CPU(S)The standard CPU features are: Intel Xeon E5-2600 v2 and E5-2600 series proc