Cisco AS5800 Operations, Administration, Maintenance, and Provisioning Guide
DOC-7810814=
Chapter 5 Maintenance
Replacement Procedures
Note If the adapter lever does not move to the locked position, the adapter is not completely
seated in the midplane. Carefully pull the adapter halfway out of the slot, reinsert it, and
place the lever in the locked position.
This completes the procedure for installing a new dial-shelf interconnect port adapter in the router shelf.
Continue with the Attaching the Dial-Shelf Interconnect Cable section on page 5-30.
Attaching the Dial-Shelf Interconnect Cable
The interconnect port adapter includes a single dial-shelf interconnect receptacle. For a redundant
connection to the dial shelf, you need to install a second port adapter.
Caution Do not use the dial-shelf interconnect port adapter for outgoing WAN connections.
Connect the dial-shelf interconnect cable as follows:
Step 1 Attach the interconnect cable directly to the RJ-45 port on the interconnect port adapter.
Step 2 Tighten the jackscrews on either side of the connector.
Step 3 Attach the other end of your interconnect cable to the port labeled Dial Shelf Interconnect on the
Cisco 5814 dial-shelf controller card.