Cisco CX-FEIP-1TX= Installation and con?guration Podręcznik Użytkownika Strona 400

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 399
Installing the CMU Chapter 5: Installation
5-78
phn-2513_004v000 (Oct 2012)
Examples of permissible Restricted Access Locations are:-
A lockable equipment room.
A lockable cabinet.
Access must only be gained by persons who have been instructed about the reasons for the
restrictions applied to the location and about any precautions that must be taken.
Mounting the CMU
Mount the CMU in one of three ways:
On a shelf or bench top.
On a wall.
In a cabinet rack.
The CMU kit contains the CMU, CMU bracket, power connector and ground lug (Figure
94).
Figure 94 CMU kit contents
To prevent the CMU from overheating, ensure that the ventilation holes on the side of the
CMU are not obstructed and that there is room for air flow across the back of the CMU
(the end opposite the connector face).
Shelf or bench top mounting
When mounting on a shelf or bench top (Figure 95), secure the CMU using its bracket. The
bracket screws to the base of the CMU.
Przeglądanie stron 399
1 2 ... 395 396 397 398 399 400 401 402 403 404 405 ... 647 648

Komentarze do niniejszej Instrukcji

Brak uwag