Cisco GoQAM Informacje Techniczne Strona 281

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 308
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 280
Power Supply 3 Parameters (Split)
4025561 Rev
A
257
Power Supply 3 Parameters (Split)
Power Supply 3 Alarm Data Parameters
Alarm Function
Major
Low
Threshold
Minor
Low
Threshold
Minor
High
Threshold
Major
High
Threshold
Hys-
teresis
Typical
Range/
Nom.
Value
Ps3PwrIn Slot 3
input power
na na na na na OK or
Fault
Ps3+24 Slot 3
+24 voltage
18.0 18.4 25.9 26.1 0.1 23.8 to
25.6
VDC
Ps3+5VDC Slot 3
+5 voltage
3.6 3.7 5.9 6.1 0.1 4.9 to
5.3 VDC
Ps3-5VDC Slot 3
-5 voltage
-5.6 -5.5 -4.6 -4.5 0.1 -5.3 to
-4.9
VDC
Power Supply 3 Control Parameters
Control Function Value Default
None
No config
variables
Power Supply 3 Manufacturing Data Parameter Examples
Manufacturing Data Typical Values
Set in Manufacturing
(example value shown)
Module Name Power Supply 3
Module Type 5013
Serial # na
Date Code na
Sw Ver na
In Service Hours na
Spec Data (MANDATA) (blank)
CLEI Code [1] na
CLLI Code [1] na
Przeglądanie stron 280
1 2 ... 276 277 278 279 280 281 282 283 284 285 286 ... 307 308

Komentarze do niniejszej Instrukcji

Brak uwag