Strona 1 - Blade Server

CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.20 JUNE 9, 2015 WWW.CISCO.COMSpec SheetCisco UCS B200 M4Blade Server

Strona 2 - CONTENTS

Cisco UCS B200 M4 Blade Server10CONFIGURING the SERVERSupported Configurations(1) One-CPU Configuration Choose one CPU from any one of the rows of Ta

Strona 3 - OVERVIEW

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER11STEP 3 CHOOSE MEMORYThe standard memory features are: DIMMs— Clock speed: 2133 MHz— Ranks per D

Strona 4 - DETAILED VIEWS

Cisco UCS B200 M4 Blade Server12CONFIGURING the SERVERChoose DIMMs and Memory MirroringSelect the memory configuration and whether or not you want the

Strona 5

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER13(2) 1-CPU configuration with memory mirroring: Select 2, 4, 8, or 12 identical DIMMs. The DIMMs

Strona 6

Cisco UCS B200 M4 Blade Server14CONFIGURING the SERVER Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 12.Caveats Syste

Strona 7

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER15 Single-rank DIMMs can be mixed with dual-rank DIMMs in the same channel Do not mix quad-rank

Strona 8 - STEP 1 VERIFY SERVER SKU

Cisco UCS B200 M4 Blade Server16CONFIGURING the SERVERSTEP 4 CHOOSE RAID CONTROLLER AND DISK DRIVE BAYSThe UCS B200 M4 can be ordered with or without

Strona 9 - STEP 2 CHOOSE CPU(S)

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER17Figure 4 UCS B200 M4 With and Without RAID Controller and Drive Bays (Top View)Figure 5 UCS

Strona 10

Cisco UCS B200 M4 Blade Server18CONFIGURING the SERVERSTEP 5 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES (OPTIONAL)The UCS B200 M4 can be ordered wi

Strona 11 - STEP 3 CHOOSE MEMORY

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER19Supported Configurations(1) 1-Drive System Select one of the drives listed in Table 7. (1) 2-Dr

Strona 12 - CONFIGURING the SERVER

Cisco UCS B200 M4 Blade Server2CONTENTSOVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3DETAIL

Strona 13 - Notes

Cisco UCS B200 M4 Blade Server20CONFIGURING the SERVERSTEP 6 CHOOSE ADAPTERSThe adapter offerings are: Cisco Virtual Interface Cards (VICs)Cisco deve

Strona 14

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER21NOTE: For environments with 6100 Series Fabric Interconnects, you must configure only the VIC 1

Strona 15

Cisco UCS B200 M4 Blade Server22CONFIGURING the SERVERChoose a Mezzanine AdapterThe supported mezzanine adapters in the UCS B200 M4 are listed in Tabl

Strona 16

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER23Supported ConfigurationsThe supported configurations are listed in Table 9. Choose one configura

Strona 17

Cisco UCS B200 M4 Blade Server24CONFIGURING the SERVERTo check that your operating system is compatible with the adapter you have selected, please che

Strona 18

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER25STEP 7 ORDER TRUSTED PLATFORM MODULE (OPTIONAL)Trusted Platform Module (TPM) is a computer chip

Strona 19

Cisco UCS B200 M4 Blade Server26CONFIGURING the SERVERSTEP 8 ORDER SECURE DIGITAL CARDS (OPTIONAL)Dual SDHC flash card sockets are provided on the fro

Strona 20 - STEP 6 CHOOSE ADAPTERS

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER27STEP 9 ORDER INTERNAL USB 2.0 DRIVE (OPTIONAL)You may order one optional internal USB 2.0 drive.

Strona 21

Cisco UCS B200 M4 Blade Server28CONFIGURING the SERVER NOTE: The figures below show a “peephole” provided on the RAID controller board where you can

Strona 22

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER29STEP 10 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARESeveral operating systems and value-adde

Strona 23

Cisco UCS B200 M4 Blade ServerOVERVIEW3OVERVIEWDelivering performance, versatility and density without compromise, the Cisco UCS B200 M4 Blade Server

Strona 24

Cisco UCS B200 M4 Blade Server30CONFIGURING the SERVERRed Hat Enterprise LinuxRHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs RequiredRHEL-2S-1G-3A RHEL/

Strona 25

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER31VMW-VS5-ENT-1A VMware vSphere 5 Enterprise for 1 Processor, 1 Year Support RqdVMW-VS5-ENT-2A VMw

Strona 26

Cisco UCS B200 M4 Blade Server32CONFIGURING the SERVERSTEP 11 CHOOSE OPERATING SYSTEM MEDIA KITChoose the optional operating system media listed in Ta

Strona 27 - Peephole

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER33STEP 12 CHOOSE SERVICE and SUPPORT LEVELA variety of service options are available, as described

Strona 28

Cisco UCS B200 M4 Blade Server34CONFIGURING the SERVERUnified Computing Warranty Plus ServiceFor faster parts replacement than is provided with the st

Strona 29

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER35See Table 17.Partner Support Service for UCS Hardware Only provides customers with replacement p

Strona 30

Cisco UCS B200 M4 Blade Server36CONFIGURING the SERVERYou can choose a service listed in Table 19.Unified Computing Drive Retention ServiceWith the Ci

Strona 31

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER37For more service and support information, see the following URL:http://www.cisco.com/en/US/servi

Strona 32 - Table 14 OS Media

Cisco UCS B200 M4 Blade Server38CONFIGURING the SERVERORDER OPTIONAL KVM LOCAL I/O CABLE*The KVM local I/O cable ships with every UCS 5100 Series blad

Strona 33

Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL39SUPPLEMENTAL MATERIALSystem BoardA top view of the UCS B200 M4 system board is shown in Figure 7.

Strona 34

Cisco UCS B200 M4 Blade Server4DETAILED VIEWSDETAILED VIEWSBlade Server Front ViewFigure 2 is a detailed front view of the Cisco UCS B200 M4 Blade Ser

Strona 35

Cisco UCS B200 M4 Blade Server40SUPPLEMENTAL MATERIALCPUs and DIMMsPhysical LayoutMemory is organized as shown in Figure 8.Figure 8 UCS B200 M4 Memo

Strona 36

Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL41— Slot 2 - E2, F2, G2, and H2 (black DIMM slots)— Slot 3 - E3, F3, G3, and H3 (white DIMM slots)T

Strona 37

Cisco UCS B200 M4 Blade Server42SUPPLEMENTAL MATERIALDIMM Population OrderPopulate the DIMMs for a CPU according to Table 23. See also Figure 9.Figure

Strona 38

Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL43Recommended Memory ConfigurationThis section explains the recommended DIMM population order rules

Strona 39 - SUPPLEMENTAL MATERIAL

Cisco UCS B200 M4 Blade Server44SUPPLEMENTAL MATERIALAdditional DIMM PopulationsThe list in Table 25 is not a complete list of all supported DIMM popu

Strona 40 - CPUs and DIMMs

Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL45Upgrade and Servicing-Related PartsThis section lists the upgrade and servicing-related parts you

Strona 41 - DIMM Population Rules

Cisco UCS B200 M4 Blade Server46SUPPLEMENTAL MATERIALAdding an Additional CPU (with CPU heat sink) or Replacing CPUsAll Cisco UCS two CPU socket-capab

Strona 42 - DIMM Population Order

Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL47CPU Heat Sink Cleaning KitThe cleaning kit is used to remove the existing thermal compound from t

Strona 43

Cisco UCS B200 M4 Blade Server48SUPPLEMENTAL MATERIALNetwork ConnectivityThis section explains how the UCS B200 M4 server connects to Fabric Interconn

Strona 44 - Additional DIMM Populations

Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL49The network adapter options are: Cisco VIC 1340/1240 adapter. This adapter plugs into the mLOM s

Strona 45

Cisco UCS B200 M4 Blade ServerBASE SERVER STANDARD CAPABILITIES and FEATURES5BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 lists the capabilit

Strona 46 - Air Baffle Replacement Kit

Cisco UCS B200 M4 Blade Server50SUPPLEMENTAL MATERIALFigure 11 VIC 1340/1240 Port ConnectivityThe number of ports available at the mezzanine adapter

Strona 47 - CPU Heat Sink Cleaning Kit

Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL51Mezzanine AdaptersThere are multiple options for the mezzanine slot: I/O-based PCIe adapters (su

Strona 48 - Network Connectivity

Cisco UCS B200 M4 Blade Server52SUPPLEMENTAL MATERIALB200 M4 Configured with 1 CPUIn a B200 M4 configured with 1 CPU, the mezzanine card slot is not u

Strona 49 - VIC 1340/1240 Adapter

Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL53In Figure 13, two ports from the VIC 1340/1240 are channeled to 2208XP Fabric Extender A and two

Strona 50

Cisco UCS B200 M4 Blade Server54SUPPLEMENTAL MATERIALConnectivity using the Cisco UCS 2204XP Fabric ExtenderThe Cisco UCS 2204XP is a second-generatio

Strona 51 - Mezzanine Adapters

Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL55In Figure 15, one port from the VIC 1340/1240 is channeled to 2204XP Fabric Extender A and one is

Strona 52 - B200 M4 Configured with 1 CPU

Cisco UCS B200 M4 Blade Server56SUPPLEMENTAL MATERIALConnectivity using the Cisco UCS 2104XP Fabric ExtenderThe option shown in Figure 16 demonstrates

Strona 53

Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL57B200 M4 Configured with 2 CPUsConnectivity using the Cisco UCS 2208XP Fabric ExtenderThe Cisco UC

Strona 54 - ■ VIC 1340/1240 to 2204XP

Cisco UCS B200 M4 Blade Server58SUPPLEMENTAL MATERIALIn Figure 18, two ports from the VIC 1340/1240 are channeled to 2208XP Fabric Extender A and two

Strona 55

Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL59Connectivity using the Cisco UCS 2204XP Fabric ExtenderThe Cisco UCS 2204XP is a second-generatio

Strona 56 - Fabric Extender

Cisco UCS B200 M4 Blade Server6BASE SERVER STANDARD CAPABILITIES and FEATURESStorage devices Up to two optional, front-accessible, hot-swappable 2.5

Strona 57

Cisco UCS B200 M4 Blade Server60SUPPLEMENTAL MATERIALIn Figure 21, one port from the VIC 1340/1240 is channeled to 2204XP Fabric Extender A and one is

Strona 58

Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL61Connectivity using the Cisco UCS 2104XP Fabric ExtenderThe options shown in Figure 23 and Figure

Strona 59

Cisco UCS B200 M4 Blade Server62TECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONSDimensions and WeightPower SpecificationsFor configuration-specific po

Strona 60

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER7CONFIGURING the SERVERFollow these steps to configure the Cisco UCS B200 M4 Blade Server: STEP 1

Strona 61

Cisco UCS B200 M4 Blade Server8CONFIGURING the SERVERSTEP 1 VERIFY SERVER SKUVerify the product ID (PID) of the server as shown in Table 2.The base Ci

Strona 62 - TECHNICAL SPECIFICATIONS

Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER9STEP 2 CHOOSE CPU(S)The standard CPU features are: Intel Xeon E5-2600 v3 series processor family