Cisco 11.0 BT Instrukcja Użytkownika Strona 6

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 30
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 5
2-6 TN3270 Design and Implementation Guide
For static LUs, the first phase is LU activation. The LU requested must be defined at the host under the PU. The
activation process is as follows:
1. The LU is activated by the host.
2. The client issues a connect with server request. If the device is listedin the table of LU names and is not being
used, then the router sends a positive response. If the device is being used, then the router sends an “in use”
response.
3. If the client connection is successful, the router sends a NOTIFY(ENABLED) request to the host.
Network Management Vector Transports (NMVTs) are also sent to any running network management
application, which allows the host to track the IP address of any device connecting to each LU.
For dynamic LUs, the first phase is session negotiation. This phase includes steps necessary to initiate the
client-to-CIP/CPA connection and to select the LU:
1. TheTN3270 client requestsa pooledLU session.The client’s request includesthe terminaltype. The TN3270
client must be configured with a destination IP address, TCP port, and terminal type for a pooled LU session
to occur.
2. The TN3270 Server forms an EBCDIC string based on the model typeand number requested by the TN3270
client.The server usesthis stringas a fieldin theREPLYproduct-set identification (PSID)NMVT fieldit sends
to the host.
3. The TN3270 Server allocates a LOCADDR from the next available LU in the LU pool for the chosen IP
address. Subject to configuration control, all LUs that the host does not immediately activate are
automatically placed in the pools. The LOCADDR is sent in the REPLY-PSID(power-on) NMVT. When
VTAM receives the NMVT, it uses the EBCDIC model type and number string to look up an LU template
under the LUGROUP. An activate logical unit (ACTLU) is sent and a terminal session is established.
The second phase is session bind and data transfer. This phase includes the steps of the TN3270 host-to-client
SNA session bind and data transfer:
1. After the ACTLU is provided by the host, the information is transferred between the system services control
point (SSCP) and the LU. The CIP manages the necessary protocol conversions. At this stage, the type of
TN3270 clientis important. If youare using a TN3270 client, SSCP mustbe configured to communicatewith
the LUusing the TN3270 data stream (using hostparameters USSTAB and SSCPFM).If TN3270E clients are
usedand theyrequestthe BIND-IMAGEfunction (normally LU1 andLU3 printers),they mustcommunicate
withSSCP usingtheSNA characterstring (SCS).In somecases,the clientLU bypassesSSCP completely(using
the host variable LOGAPPL) and connects directly to a host application.
2. When the LU data is received by the SSCP, it requests a bind with the LU, which is locally acknowledged by
the CIP/CPA.
3. The LU-to-LU data is transferred.
The third phase is session termination. Sessions are terminated in the following conditions:
• The client logs off the LU-to-LU session, causing the server to send an UNBIND message followed by a
NOTIFY (UNAVAIL) message to the host.
• The client disconnects at the TCP layer and the LU is configured to disconnect on UNBIND. The TCP session
is disconnected and the host is sent a NOTIFY (UNAVAIL) message.
• The client is idle too long or will not respond to a DO TIMING MARK message. The server sends UNBIND
message to the host and then sends a NOTIFY (UNAVAIL) message.
Przeglądanie stron 5
1 2 3 4 5 6 7 8 9 10 11 ... 29 30

Komentarze do niniejszej Instrukcji

Brak uwag