Cisco UCSB-B200-M3-CH Arkusz Danych

Przeglądaj online lub pobierz Arkusz Danych dla Kluczowe komponenty serwerowe Cisco UCSB-B200-M3-CH. Cisco UCS B200 M3 Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Blade Server

CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV C.6 MAY 27, 2014 WWW.CISCO.COMSpec SheetCisco UCS B200 M3Blade Server

Strona 2

Cisco UCS B200 M3 Blade Server10CONFIGURING the SERVERSupported Configurations(1) One-CPU Configuration Choose one CPU from any one of the rows of Ta

Strona 3 - OVERVIEW

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER11— The connectivity options are:• VIC 1240 installed in VIC 1240 slot and no adapter installed in

Strona 4 - DETAILED VIEWS

Cisco UCS B200 M3 Blade Server12CONFIGURING the SERVERSTEP 3 CHOOSE MEMORYThe standard memory features are: DIMMs— Clock speed: 1866, 1600, or 1333 M

Strona 5

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER13Choose DIMMs and Memory MirroringSelect the memory configuration and whether or not you want the

Strona 6

Cisco UCS B200 M3 Blade Server14CONFIGURING the SERVERSupported Configurations(1) B200 M3 configured with 1 CPU without memory mirroring Select from

Strona 7

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER15(3) B200 M3 configured with 2 CPUs without memory mirroring: Select from 1 to 12 DIMMs per CPU

Strona 8 - STEP 1 VERIFY SERVER SKU

Cisco UCS B200 M3 Blade Server16CONFIGURING the SERVERCaveats System speed is dependent on how many DIMMs are populated per channel. See Table 7 for

Strona 9 - STEP 2 CHOOSE CPU(S)

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER17— DIMM choice— DIMM population (how many DIMMs per channel are populated)— BIOS setting. For the

Strona 10 - Notes

Cisco UCS B200 M3 Blade Server18CONFIGURING the SERVERSTEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES (OPTIONAL)The UCS B200 M3 can be ordered wi

Strona 11

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER19Supported Configurations(1) 1-Drive System Select one of the drives listed in Table 8. (1) 2-Dr

Strona 12 - STEP 3 CHOOSE MEMORY

Cisco UCS B200 M3 Blade Server2OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3DETAILED VIEWS

Strona 13

Cisco UCS B200 M3 Blade Server20CONFIGURING the SERVERSTEP 5 CHOOSE ADAPTERSThe adapter offerings are: Cisco Virtual Interface Cards (VICs)Cisco deve

Strona 14

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER21Supported Configurations(1) B200 M3 configured with 1 CPUFor a B200 M3 configured with 1 CPU, th

Strona 15

Cisco UCS B200 M3 Blade Server22CONFIGURING the SERVER(2) B200 M3 configured with 2 CPUsFor a B200 M3 configured with 2 CPUs, the supported configurat

Strona 16

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER23STEP 6 ORDER A TRUSTED PLATFORM MODULETrusted Platform Module (TPM) is a computer chip (microcon

Strona 17 - CONFIGURING the SERVER

Cisco UCS B200 M3 Blade Server24CONFIGURING the SERVERSTEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDSDual SDHC flash card sockets are provided

Strona 18

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER25STEP 8 ORDER OPTIONAL INTERNAL USB 2.0 DRIVEYou may order one optional internal USB 2.0 drive. T

Strona 19

Cisco UCS B200 M3 Blade Server26CONFIGURING the SERVERSTEP 9 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARESeveral operating systems and value-added

Strona 20 - STEP 5 CHOOSE ADAPTERS

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER27Red Hat Enterprise LinuxRHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs RequiredRHEL-2S-1G-3A RHEL/

Strona 21

Cisco UCS B200 M3 Blade Server28CONFIGURING the SERVERVMware 5VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support RqdVMW-VS5-STD

Strona 22

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER29STEP 10 CHOOSE OPERATING SYSTEM MEDIA KITChoose the optional operating system media listed in Ta

Strona 23

Cisco UCS B200 M3 Blade ServerOVERVIEW3OVERVIEWDelivering performance, versatility and density without compromise, the Cisco UCS B200 M3 Blade Server

Strona 24

Cisco UCS B200 M3 Blade Server30CONFIGURING the SERVERSTEP 11 CHOOSE SERVICE and SUPPORT LEVELA variety of service options are available, as described

Strona 25

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER31Unified Computing Warranty Plus ServiceFor faster parts replacement than is provided with the st

Strona 26

Cisco UCS B200 M3 Blade Server32CONFIGURING the SERVERPartner Support Service for UCS provides hardware and software support, including triage support

Strona 27

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER33You can choose a service listed in Table 21.Unified Computing Drive Retention ServiceWith the Ci

Strona 28

Cisco UCS B200 M3 Blade Server34CONFIGURING the SERVERFor more service and support information, see the following URL:http://www.cisco.com/en/US/servi

Strona 29

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER35ORDER OPTIONAL KVM LOCAL I/O CABLE*The KVM local I/O cable ships with every UCS 5100 Series blad

Strona 30

Cisco UCS B200 M3 Blade Server36SUPPLEMENTAL MATERIALSUPPLEMENTAL MATERIALSystem BoardA top view of the UCS B200 M3 system board is shown in Figure 5.

Strona 31

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL37CPUs and DIMMsPhysical LayoutMemory is organized as shown in Figure 6.Figure 6 UCS B200 M3 Memo

Strona 32

Cisco UCS B200 M3 Blade Server38SUPPLEMENTAL MATERIAL— Bank 1 - E1, F1, G1, and H1 (black DIMM slots)— Bank 2 - E2, F2, G2, and H2 (white DIMM slots)T

Strona 33

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL39DIMM Population Rules When considering the memory configuration of your server, you should take i

Strona 34

Cisco UCS B200 M3 Blade Server4DETAILED VIEWSDETAILED VIEWSBlade Server Front ViewFigure 2 is a detailed front view of the Cisco UCS B200 M3 Blade Ser

Strona 35

Cisco UCS B200 M3 Blade Server40SUPPLEMENTAL MATERIALDIMM Population OrderPopulate the DIMMs for a CPU according to Table 25.Table 25 DIMM Populatio

Strona 36 - SUPPLEMENTAL MATERIAL

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL41Recommended Memory ConfigurationThis section explains the recommended DIMM population order rules

Strona 37 - CPUs and DIMMs

Cisco UCS B200 M3 Blade Server42SUPPLEMENTAL MATERIAL192 GB4x8 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB10663244x16 GB 2x16 GB — 4x16 GB 2x16 GB — 1866 12

Strona 38

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL4396 GB4x4 GB 4x4 GB 4x4 GB 4x4 GB 4x4 GB 4x4 GB 1066 244x8 GB 2x8 GB — 4x8 GB 2x8 GB — 1600 123x16

Strona 39 - DIMM Population Rules

Cisco UCS B200 M3 Blade Server44SUPPLEMENTAL MATERIALAdditional DIMM PopulationsThe list in Table 28 is not a complete list of all supported DIMM popu

Strona 40 - DIMM Population Order

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL45Upgrade and Servicing-Related PartsThis section lists the upgrade and servicing-related parts you

Strona 41

Cisco UCS B200 M3 Blade Server46SUPPLEMENTAL MATERIALAdding an Additional CPU (with CPU heat sink)All Cisco UCS two CPU socket-capable servers can be

Strona 42

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL47Air Baffle Replacement KitAir baffles are designed to direct airflow through the server to mainta

Strona 43

Cisco UCS B200 M3 Blade Server48SUPPLEMENTAL MATERIALNEBS ComplianceWhen configured with the specific set of components shown in Table 30, the UCS B20

Strona 44 - Additional DIMM Populations

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL49Network ConnectivityThis section explains how the UCS B200 M3 server connects to Fabric Interconn

Strona 45

Cisco UCS B200 M3 Blade ServerBASE SERVER STANDARD CAPABILITIES and FEATURES5BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 lists the capabilit

Strona 46 - Motherboard Lithium Battery

Cisco UCS B200 M3 Blade Server50SUPPLEMENTAL MATERIALThe network adapter options are: Cisco VIC 1240 adapter. This adapter plugs into the VIC 1240 sl

Strona 47 - CPU Heat Sink Cleaning Kit

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL51Figure 9 VIC 1240 Port ConnectivityThe number of ports available at the mezzanine adapter depen

Strona 48 - NEBS Compliance

Cisco UCS B200 M3 Blade Server52SUPPLEMENTAL MATERIAL— QLogic M73KR-Q Cisco Storage Accelerator adapters— Cisco UCS 785 GB MLC Fusion-io ioDrive2— LS

Strona 49 - Network Connectivity

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL53In Figure 11, two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are c

Strona 50 - VIC 1240 Adapter

Cisco UCS B200 M3 Blade Server54SUPPLEMENTAL MATERIALFigure 12 Option 1 - VIC 1240 to UCS 2204XP Fabric Extender (no mezzanine adapter)In Figure 13,

Strona 51 - Mezzanine Adapters

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL55Connectivity using the Cisco UCS 2104XP Fabric ExtenderThe option shown in Figure 14 demonstrates

Strona 52 - B200 M3 Configured with 1 CPU

Cisco UCS B200 M3 Blade Server56SUPPLEMENTAL MATERIALB200 M3 Configured with 2 CPUsConnectivity using the Cisco UCS 2208XP Fabric ExtenderThe Cisco UC

Strona 53 - ■ VIC 1240 to 2204XP

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL57In Figure 16, two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are c

Strona 54

Cisco UCS B200 M3 Blade Server58SUPPLEMENTAL MATERIALIn Figure 18, two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are c

Strona 55 - Fabric Extender

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL59Connectivity using the Cisco UCS 2204XP Fabric ExtenderThe Cisco UCS 2204XP is a second-generatio

Strona 56

Cisco UCS B200 M3 Blade Server6BASE SERVER STANDARD CAPABILITIES and FEATURESVideo The Cisco Integrated Management Controller (CIMC) provides video:

Strona 57

Cisco UCS B200 M3 Blade Server60SUPPLEMENTAL MATERIALIn Figure 21, one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is chan

Strona 58

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL61In Figure 23, one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is chan

Strona 59

Cisco UCS B200 M3 Blade Server62SUPPLEMENTAL MATERIALConnectivity using the Cisco UCS 2104XP Fabric ExtenderThe options shown in Figure 25 and Figure

Strona 60

Cisco UCS B200 M3 Blade ServerTECHNICAL SPECIFICATIONS63TECHNICAL SPECIFICATIONSDimensions and WeightPower SpecificationsFor configuration-specific po

Strona 61

Cisco UCS B200 M3 Blade Server64TECHNICAL SPECIFICATIONS

Strona 62

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER7CONFIGURING the SERVERFollow these steps to configure the Cisco UCS B200 M3 Blade Server: STEP 1

Strona 63 - TECHNICAL SPECIFICATIONS

Cisco UCS B200 M3 Blade Server8CONFIGURING the SERVERSTEP 1 VERIFY SERVER SKUVerify the product ID (PID) of the server as shown in Table 2.The base Ci

Strona 64

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER9STEP 2 CHOOSE CPU(S)The standard CPU features are: Intel Xeon E5-2600 v2 and E5-2600 series proc

Komentarze do niniejszej Instrukcji

Brak uwag