3-3
Catalyst 6500 Series Switch Module Installation Guide
78-15725-02
Chapter 3 Installing the Module
Installing a Supervisor Engine or a Switching Module
You should install switching-module filler plates (Cisco part number
800-00292-01) in any empty slots to maintain consistent airflow through the
switch chassis.
Caution To prevent ESD damage, handle modules by the carrier edges only.
Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the
module.
Warning
Invisible laser radiation may be emitted from disconnected fibers or
connectors. Do not stare into beams or view directly with optical instruments.
Statement 1051
Table 3-1 Supervisor Engine Slot Assignments
Supervisor Engine Slot Assignments
Supervisor Engine 1A
Slots 1 and 2 (3-slot chassis)
Slots 1 and 2 (6-slot chassis)
Slots 1 and 2 (9-slot chassis)
Supervisor Engine 2
Slots 1 and 2 (3-slot chassis)
Slots 1 and 2 (6-slot chassis)
Slots 1 and 2 (9-slot chassis
Slots 1 and 2 (13-slot chassis)
Supervisor Engine 720
Slots 1 and 2 (3-slot chassis)
Slots 5 and 6 (6-slot chassis)
Slots 5 and 6 (9-slot chassis)
Slots 7 and 8 (13-slot chassis)