Chapter 7. Configuring the Cisco 3012 InfiniBand to Ethernet gateway 125
4. Commit the new Bridge Group information and review (step 4 on page 129).
5. Save the 3012 config to NVRAM (step 5 on page 130).
6. Configure the upstream 4948 to match the Ethernet Gateway configuration (step 6 on
page 130).
7. Test the configurations by pinging from the InfiniBand client to the default gateway on the
4948 (step 7 on page 131).
7.3.4 Detailed steps to implement a simple bridge group design
To implement a simple bridge group design, follow these detailed steps:
1. To create our first bridge group, from the Element Manager GUI, click Ethernet
Bridging (see Figure 7-5).
Figure 7-5 First step in creating a bridge group through the Element Manager GUI
Tip: The default user ID and password for the 3012 is super/super.