
network-clock-priority
MOD-20
Release 12.0(4) T
If the chosen clocking port becomes inactive, the system searches for clock on the active
TE-configured ports in the following order:
1 Ports configured as network-clock-priority high in order from lowest (1) to highest (4).
2 Ports configured as network-clock-priority low in order from lowest (1) to highest (4).
If the originally chosen port then reactivates, it resumes its role as clock source regardless of its
network-clock-priority setting.
If you enter either the no network-clock-priority low or the no network-clock-priority high
command, the network clock priority defaults to low.
Example
The following example configures BRI voice port 1 as a first priority clock source:
interface bri 1
network-clock-priority high
Related Commands
Command Description
network-clock-select Specifies a selection hierarchy for the clock sources.
Komentarze do niniejszej Instrukcji