1-4
Cisco AS5400XM Universal Gateway Chassis Installation Guide
OL-6418-02
Chapter 1 Overview
Specifications
The output of each power module is rated at 300 watts (nonredundant mode), and is composed of four
independent output voltages: 3.3V, 5V, 12V and –12V. AC input units have power factor correction and
low harmonic distortion. Units that are in redundant mode run at one-half the power capability. If a
power supply failure occurs, these units are capable of powering the complete system either at the input
side or the DC load side. Power failures are reported through environmental monitoring software.
Note The grounding architecture for the Cisco AS5400XM universal gateway is isolated DC return (DC-I).
Specifications
Table 1-1 provides system specifications for the Cisco AS5400XM universal gateway.
Ta b l e 1-1 Specifications
Description Specification
Dimensions (H x W x D) 3.5 x 17.5 x 18.25 in. (8.89 x 44.45 x 46.36 cm)
Weight 35 lb maximum (15.8 kg)
Processor 250 MHz (Cisco AS5400XM universal gateway)
Operating environment 32 to 104° F (0 to 40° C)
Nonoperating temperature –40 to 185° F (–40 to 85° C)
Operating humidity 5 to 95%, noncondensing
Noise level 70 dB
1
@ 3 ft (0.914 m)
1. dB = decibels.
Input voltage, AC power supply
Current
Frequency
Power factor
Input AC power
100 to 240 VAC
2
; –10%, +6% tolerance
5 to 2A
50/60 Hz
0.80 to 0.95
200 to 400W (maximum)
2. VAC = volts alternating current.
Input voltage, DC power supply
Maximum input current
Typical input current
Efficiency
Input DC power
–48 to –60 VDC
3
; –10%, +6% tolerance
9.0A
2.0 to 4.0A
63%
200 to 400W (maximum)
3. VDC = volts direct current.
WAN interface options T1, E1, T3
Serial interfaces (for backhaul WAN support) 2 serial line interfaces
LAN interface options Gigabit Ethernet 10/100/1000BASE-T (RJ-45)
Console and auxiliary ports Asynchronous serial (RJ-45)
Regulatory compliance See the Regulatory Compliance and Safety
Information publication that came with your gateway.