Table 9. Cisco AS5400XM Universal Gateway Call-Capacity Table
Feature Description
Voice Call Capacities
Direct inward dialing (DID)
672
Calls using TCL IVR
672
Voicemail
480
VoiceXML
192 with DSPs and trunk interfaces
240 with DTMF interaction only; no ASR/TTS, no trunk cards, and no DSPs
TDM switching
1344 (2 CT3s) without DSP (PRI or SS7)
648 with DSP (CAS or E1 R2)
Dial Call Capacity
Asynchronous-mode PPP, synchronous-mode PPP,
MLPPP, and TCP Clear
648 DS-0s in use
Microsoft Point-to-Point Compression (MPPC)
460 asynchronous and 360 synchronous
Table 10. Cisco AS5400XM Universal Gateway Compliance Data
Certification Requirements
NEBS certification
Telcordia SR-3580
GR-1089-CORE, Issue 2
GR-63-CORE, Issue 1
Level 3 certification based on usage and critical nature of equipment
All equipment Common Language Equipment Identifier (CLEI) coded
Available in TIRKS database
Safety certifications
UL 1950, third edition
CSA 950, third edition
EN 60950, with Amendments 1, 2, 3, and 4
IEC 60950
AS/NZS 3260
TS 001
Electromagnetic Emissions and Immunity Compliance
EN 55022B (CISPR22)
EN 300386
NZS/AS3548 Class A
VCCI B
FCC 47CR15 Class A
BITS Clock
Stratum Layer 4E-compliant
Table 11. Cisco AS5400XM Universal Gateway Environmental Specifications
Feature Description
Heat Dissipation
1190 Btu/hr (maximum); 525 Btu/hr (typical)
AC Power Cable Supplied with AC Systems
Redundant power supply: 18 AWG, 15-amp IEC 320 Type C5 standard cable
DC Power Cable Required for DC Systems
12-14 AWG stranded copper wire
Storage Temperature
-40 to 185ºF (-40 to 85ºC)
Acoustics
55 dBA maximum; sound pressure level at 1m
Humidity
5 to 95 percent, noncondensing
Altitude
-200 to 10,000 ft (-60 to 3,050m)
Reliability (at 104ºF [40ºC], 120 VAC and -48 VDC,
140W)
165,000 hours MTBF per chassis