Strona 1 - Platform

Prisma® and Prisma II™ Platform Maintenance and Troubleshooting

Strona 2 - Important

Contents, Continued viii 4000326 Rev A Troubleshoot Alarm Conditions...

Strona 3

1-84 Transmitters 4000326 Rev A Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect pro

Strona 4 - Notices

4000326 Rev A Transmitters 1-85 Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean a fi

Strona 5

1-86 Transmitters 4000326 Rev A Section F Prisma II 1310 nm Reverse Transmitter Overview Introduction The information in this section applies to the

Strona 6

4000326 Rev A Transmitters 1-87 Monitor Alarm Parameters Using the ICIM Introduction The Intelligent Communications Interface Module (ICIM) in the P

Strona 7

1-88 Transmitters 4000326 Rev A Monitor Alarm Parameters Using the ICIM, Continued Monitoring Alarm Parameters From the MAIN or SCROLL menus on the

Strona 8

4000326 Rev A Transmitters 1-89 Monitor Status Parameters Using the ICIM Introduction The STATUS menu on the ICIM allows you to verify the status of

Strona 9

1-90 Transmitters 4000326 Rev A Monitor Status Parameters Using the ICIM, Continued Monitoring Status Parameters From the MAIN or SCROLL menus on th

Strona 10 - Contents

4000326 Rev A Transmitters 1-91 Configure Parameters Using the ICIM Introduction The CONFIG menu on the ICIM allows you to configure several transmi

Strona 11

1-92 Transmitters 4000326 Rev A Monitor Alarm Parameters Using LCI Introduction The Local Craft Interface (LCI) software allows you to view alarms t

Strona 12 - Safety Precautions

4000326 Rev A Transmitters 1-93 Monitor Alarm Parameters Using LCI, Continued Monitoring Alarm Parameters To monitor the alarms, navigate to the Mod

Strona 13

Contents, Continued 4000326 Rev A ix Chapter 5 Chassis Overview...

Strona 14 - Laser Safety

1-94 Transmitters 4000326 Rev A Modify Alarm Limits Using LCI Introduction Using LCI, you can modify limits for several alarm parameters for the tra

Strona 15 - Preface

4000326 Rev A Transmitters 1-95 Monitor Status Parameters Using LCI Introduction The LCI software allows you to verify the status of the transmitter

Strona 16

1-96 Transmitters 4000326 Rev A Monitor Status Parameters Using LCI, Continued Monitoring Status Parameters To monitor the parameters, navigate to t

Strona 17 - Transmitters

4000326 Rev A Transmitters 1-97 Configure Parameters Using LCI Introduction The LCI software allows you to configure several transmitter parameters.

Strona 18

1-98 Transmitters 4000326 Rev A General Troubleshooting Information Introduction The following information: • Lists the equipment you might need to

Strona 19

4000326 Rev A Transmitters 1-99 Troubleshoot Alarm Conditions Introduction The following troubleshooting information helps identify possible causes

Strona 20

1-100 Transmitters 4000326 Rev A Transmitter Maintenance Schedule Introduction Regular maintenance is required to extend the life of the transmitter

Strona 21

4000326 Rev A Transmitters 1-101 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect pr

Strona 22

1-102 Transmitters 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean a f

Strona 23

4000326 Rev A Transmitters 1-103 Section G Prisma II 1550 nm Transmitters Overview Introduction The information in this section applies to the follo

Strona 24

x 4000326 Rev A Safety Precautions Protect Yourself From Electric Shock and Your System From Damage! • The products described in this document com

Strona 25

1-104 Transmitters 4000326 Rev A Monitor Alarm Parameters Using the ICIM Introduction The Intelligent Communications Interface Module (ICIM) in the

Strona 26

4000326 Rev A Transmitters 1-105 Monitor Alarm Parameters Using the ICIM, Continued Monitoring Alarm Parameters From the MAIN or SCROLL menus on the

Strona 27

1-106 Transmitters 4000326 Rev A Monitor Alarm Parameters Using the ICIM, Continued Parameter Meaning Typical Range Possible Solutions to Alarm PsO

Strona 28

4000326 Rev A Transmitters 1-107 Monitor Status Parameters Using the ICIM Introduction The STATUS menu on the ICIM allows you to verify the status o

Strona 29

1-108 Transmitters 4000326 Rev A Monitor Status Parameters Using the ICIM, Continued Monitoring Status Parameters From the MAIN or SCROLL menus on t

Strona 30

4000326 Rev A Transmitters 1-109 Monitor Status Parameters Using the ICIM, Continued Parameter Units Meaning Typical Value -12VInt V Internal -

Strona 31

1-110 Transmitters 4000326 Rev A Configure Parameters Using the ICIM Introduction The CONFIG menu on the ICIM allows you to configure several transm

Strona 32

4000326 Rev A Transmitters 1-111 Monitor Alarm Parameters Using LCI Introduction The Local Craft Interface (LCI) software allows you to view alarms

Strona 33

1-112 Transmitters 4000326 Rev A Monitor Alarm Parameters Using LCI, Continued Monitoring Alarm Parameters To monitor the alarms, navigate to the Mo

Strona 34

4000326 Rev A Transmitters 1-113 Monitor Alarm Parameters Using LCI, Continued Parameter Typical Range Possible Solutions to Alarm Laser Enabled

Strona 35

4000326 Rev A xi Safety Precautions, Continued Safe Software Operation The software described in this guide is used to monitor and/or control Scien

Strona 36

1-114 Transmitters 4000326 Rev A Modify Alarm Limits Using LCI Introduction Using LCI, you can modify limits for several alarm parameters for the tr

Strona 37

4000326 Rev A Transmitters 1-115 Monitor Status Parameters Using LCI Introduction The LCI software allows you to verify the status of the transmitte

Strona 38

1-116 Transmitters 4000326 Rev A Monitor Status Parameters Using LCI, Continued Monitoring Status Parameters To monitor the parameters, navigate to

Strona 39

4000326 Rev A Transmitters 1-117 Configure Parameters Using LCI Introduction The LCI software allows you to configure several transmitter parameters

Strona 40

1-118 Transmitters 4000326 Rev A General Troubleshooting Information Introduction The following information: • Lists the equipment you might need t

Strona 41

4000326 Rev A Transmitters 1-119 Troubleshoot Alarm Conditions Introduction The following troubleshooting information helps identify possible causes

Strona 42

1-120 Transmitters 4000326 Rev A Transmitter Maintenance Schedule Introduction Regular maintenance is required to extend the life of the transmitter

Strona 43

4000326 Rev A Transmitters 1-121 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect pr

Strona 44

1-122 Transmitters 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean a f

Strona 45

4000326 Rev A Receivers 2-1 Chapter 2 Receivers Overview Introduction This chapter provides information to assist you in maintaining and troubleshoo

Strona 46

xii 4000326 Rev A Laser Safety Introduction Each product described in this guide does one of the following: • Contains an infrared laser that tran

Strona 47

2-2 Receivers 4000326 Rev A Section A Prisma Model 6971-SF Single Forward Receiver Overview Introduction The information in this section applies to

Strona 48

4000326 Rev A Receivers 2-3 Monitor Alarm Parameters Introduction From the ALARMS screen on the receiver, you can determine whether there is a recei

Strona 49

2-4 Receivers 4000326 Rev A Monitor Alarm Parameters, Continued ALARMS Screen Description The ALARMS screens let you quickly determine the cause of

Strona 50

4000326 Rev A Receivers 2-5 Monitor Alarm Parameters, Continued Monitoring Alarm Parameters The following table describes each alarm parameter. Par

Strona 51

2-6 Receivers 4000326 Rev A Monitor Status Parameters Introduction From the STATUS screen on the receiver, you can check various parameters to verif

Strona 52

4000326 Rev A Receivers 2-7 Monitor Status Parameters, Continued STATUS Screen Description The first STATUS screen is called the Summary STATUS scre

Strona 53

2-8 Receivers 4000326 Rev A Monitor Status Parameters, Continued Monitoring Status Parameters The following table describes each status parameter.

Strona 54

4000326 Rev A Receivers 2-9 Monitor Status Parameters, Continued Parameter Meaning Values OK, HIGH or LOW -5Vdc -5 V backplane power level 0 V

Strona 55

2-10 Receivers 4000326 Rev A General Troubleshooting Information Introduction The following information: • Lists the equipment you might need to tr

Strona 56

4000326 Rev A Receivers 2-11 Troubleshoot Alarm Conditions Introduction The information in this section provides possible solutions to the following

Strona 57

4000326 Rev A Preface xiii Preface About This Guide Introduction This guide provides maintenance and troubleshooting information for the Prisma® and

Strona 58

2-12 Receivers 4000326 Rev A Troubleshoot Alarm Conditions, Continued Troubleshooting Receiver Alarms The following table shows the possible causes

Strona 59

4000326 Rev A Receivers 2-13 Troubleshoot Alarm Conditions, Continued Troubleshooting Power Supply Alarms The following table shows the possible cau

Strona 60

2-14 Receivers 4000326 Rev A Troubleshoot Alarm Conditions, Continued Alarm Status Possible Causes Possible Solutions Backplane Power Supply Sta

Strona 61

4000326 Rev A Receivers 2-15 Receiver Maintenance Schedule Introduction Regular maintenance is required to extend the life of the receiver and to en

Strona 62 - Transmitter Specifications

2-16 Receivers 4000326 Rev A Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect proble

Strona 63

4000326 Rev A Receivers 2-17 Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean a fiber

Strona 64

2-18 Receivers 4000326 Rev A Section B Prisma Model 6971-HP High Power Receiver Overview Introduction The information in this section applies to the

Strona 65

4000326 Rev A Receivers 2-19 Monitor Alarm Parameters Introduction From the ALARMS screen on the receiver, you can determine whether there is a rece

Strona 66

2-20 Receivers 4000326 Rev A Monitor Alarm Parameters, Continued Alarm Parameters The following table describes each alarm parameter. Parameter Mea

Strona 67

4000326 Rev A Receivers 2-21 Monitor Status Parameters Introduction While viewing the STATUS screen on the receiver, you can press the Select key

Strona 69

2-22 Receivers 4000326 Rev A Monitor Status Parameters, Continued Status Parameters The following table describes each status parameter. Parameter

Strona 70

4000326 Rev A Receivers 2-23 Receiver Specifications Introduction The specifications listed in the following tables can be useful when troubleshooti

Strona 71

2-24 Receivers 4000326 Rev A Receiver Specifications, Continued Optical Specifications Parameter Values Bandwidth 50–870 MHz Frequency response ±

Strona 72

4000326 Rev A Receivers 2-25 General Troubleshooting Information Introduction If you experience a receiver alarm condition, verify that the receiver

Strona 73

2-26 Receivers 4000326 Rev A Receiver Maintenance Schedule Introduction Regular maintenance is required to extend the life of the receiver and to en

Strona 74

4000326 Rev A Receivers 2-27 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect proble

Strona 75

2-28 Receivers 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean a fiber

Strona 76

4000326 Rev A Receivers 2-29 Section C Prisma Model 6971-DR Dual Reverse Receiver Overview Introduction The information in this section applies to t

Strona 77

2-30 Receivers 4000326 Rev A Monitor Alarm Parameters Introduction From the ALARMS screen on the receiver, you can determine whether there is a rece

Strona 78

4000326 Rev A Receivers 2-31 Monitor Alarm Parameters, Continued ALARMS Screen Description The ALARMS screens let you quickly determine the cause of

Strona 79

4000326 Rev A Transmitters 1-1 Chapter 1 Transmitters Overview Introduction This chapter provides information to assist you in maintaining and troub

Strona 80

2-32 Receivers 4000326 Rev A Monitor Alarm Parameters, Continued Parameter Meaning Values HIGH: Above 16.50 V 15Vdc +15 V DC power level LOW: B

Strona 81

4000326 Rev A Receivers 2-33 Monitor Status Parameters Introduction From the STATUS screen on the receiver, you can check various parameters to veri

Strona 82

2-34 Receivers 4000326 Rev A Monitor Status Parameters, Continued STATUS Screen Description The first STATUS screen is called the Summary STATUS scr

Strona 83

4000326 Rev A Receivers 2-35 Monitor Status Parameters, Continued Monitoring Status Parameters The following table describes each status parameter.

Strona 84

2-36 Receivers 4000326 Rev A Monitor Status Parameters, Continued Parameter Meaning Values Popt1 LOW RX 1 has a low optical power level (-3.0 d

Strona 85

4000326 Rev A Receivers 2-37 Receiver Specifications Introduction The specifications listed in the following tables can be useful when troubleshooti

Strona 86

2-38 Receivers 4000326 Rev A Receiver Specifications, Continued RF Output Specifications Notes: • RF output level is specified for video carrier

Strona 87

4000326 Rev A Receivers 2-39 General Troubleshooting Information Introduction If you experience a receiver alarm condition, verify that the receiver

Strona 88

2-40 Receivers 4000326 Rev A Receiver Maintenance Schedule Introduction Regular maintenance is required to extend the life of the receiver and to en

Strona 89

4000326 Rev A Receivers 2-41 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect proble

Strona 90

1-2 Transmitters 4000326 Rev A Section A Prisma Model 6473 Forward Transmitters Overview Introduction The information in this section applies to the

Strona 91

2-42 Receivers 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean a fiber

Strona 92

4000326 Rev A Receivers 2-43 Section D Prisma II Forward Receiver Overview Introduction The information in this section applies to the Prisma II For

Strona 93

2-44 Receivers 4000326 Rev A Monitor Alarm Parameters Using the ICIM Introduction The Intelligent Communications Interface Module (ICIM) in the Pris

Strona 94

4000326 Rev A Receivers 2-45 Monitor Alarm Parameters Using the ICIM, Continued Monitoring Alarm Parameters From the MAIN or SCROLL menus on the ICI

Strona 95

2-46 Receivers 4000326 Rev A Monitor Status Parameters Using the ICIM Introduction The STATUS menu on the ICIM allows you to verify the status of th

Strona 96

4000326 Rev A Receivers 2-47 Monitor Status Parameters Using the ICIM, Continued Monitoring Status Parameters From the MAIN or SCROLL menus on the I

Strona 97

2-48 Receivers 4000326 Rev A Configure Parameters Using the ICIM Introduction The CONFIG menu on the ICIM allows you to configure several receiver p

Strona 98

4000326 Rev A Receivers 2-49 Monitor Alarm Parameters Using LCI Introduction The Local Craft Interface (LCI) software allows you to view alarms that

Strona 99

2-50 Receivers 4000326 Rev A Monitor Alarm Parameters Using LCI, Continued Monitoring Alarm Parameters To monitor the alarms, navigate to the Module

Strona 100 - Required Materials

4000326 Rev A Receivers 2-51 Modify Alarm Limits Using LCI Introduction Using LCI, you can modify limits for several alarm parameters for the receiv

Strona 101 - Continued

4000326 Rev A Transmitters 1-3 Monitor Alarm Parameters Introduction From the ALARMS screen on the transmitter, you can determine whether there is a

Strona 102 - Section F

2-52 Receivers 4000326 Rev A Monitor Status Parameters Using LCI Introduction The LCI software allows you to verify the status of the receiver. Stat

Strona 103 - Alarm Limits

4000326 Rev A Receivers 2-53 Configure Parameters Using LCI Introduction The LCI software allows you to configure several receiver parameters. Confi

Strona 104

2-54 Receivers 4000326 Rev A General Troubleshooting Information Introduction The following information: • Lists the equipment you might need to tr

Strona 105 - Status Information

4000326 Rev A Receivers 2-55 Troubleshoot Alarm Conditions Introduction The following troubleshooting information helps identify possible causes and

Strona 106

2-56 Receivers 4000326 Rev A Receiver Maintenance Schedule Introduction Regular maintenance is required to extend the life of the receiver and to en

Strona 107 - Configuring Parameters

4000326 Rev A Receivers 2-57 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect proble

Strona 108

2-58 Receivers 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean a fiber

Strona 109

4000326 Rev A Receivers 2-59 Section E Prisma II Reverse Video Receiver and Reverse Data Receiver Overview Introduction The information in this sect

Strona 110 - Modifying Alarm Parameters

2-60 Receivers 4000326 Rev A Monitor Alarm Parameters Using the ICIM Introduction The Intelligent Communications Interface Module (ICIM) in the Pris

Strona 111

4000326 Rev A Receivers 2-61 Monitor Alarm Parameters Using the ICIM, Continued Monitoring Alarm Parameters From the MAIN or SCROLL menus on the ICI

Strona 112

Please Read This Entire Guide Important Please read this entire guide before you install or operate this product. Give particular attention to all saf

Strona 113

1-4 Transmitters 4000326 Rev A Monitor Alarm Parameters, Continued ALARMS Screen Description The ALARMS screens let you quickly determine the cause

Strona 114 - Troubleshooting Precautions

2-62 Receivers 4000326 Rev A Monitor Status Parameters Using the ICIM Introduction The STATUS menu on the ICIM allows you to verify the status of th

Strona 115 - Troubleshooting Alarms

4000326 Rev A Receivers 2-63 Configure Parameters Using the ICIM Introduction The CONFIG menu on the ICIM allows you to configure several receiver p

Strona 116 - Required Maintenance

2-64 Receivers 4000326 Rev A Monitor Alarm Parameters Using LCI Introduction The Local Craft Interface (LCI) software allows you to view alarms that

Strona 117

4000326 Rev A Receivers 2-65 Monitor Alarm Parameters Using LCI, Continued Monitoring Alarm Parameters To monitor the alarms, navigate to the Module

Strona 118

2-66 Receivers 4000326 Rev A Monitor Status Parameters Using LCI Introduction The LCI software allows you to verify the status of the receiver. Stat

Strona 119 - Section G

4000326 Rev A Receivers 2-67 Configure Parameters Using LCI Introduction The LCI software allows you to configure several receiver parameters. Confi

Strona 120

2-68 Receivers 4000326 Rev A General Troubleshooting Information Introduction The following information: • Lists the equipment you might need to tr

Strona 121

4000326 Rev A Receivers 2-69 Troubleshoot Alarm Conditions Introduction The following troubleshooting information helps identify possible causes and

Strona 122

2-70 Receivers 4000326 Rev A Receiver Maintenance Schedule Introduction Regular maintenance is required to extend the life of the receiver and to en

Strona 123

4000326 Rev A Receivers 2-71 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect proble

Strona 124

4000326 Rev A Transmitters 1-5 Monitor Alarm Parameters, Continued Monitoring Alarm Parameters for Models 6473-NC Overlay and 750 MHz Forward Transm

Strona 125

2-72 Receivers 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean a fiber

Strona 126

4000326 Rev A Optical Switches 3-1 Chapter 3 Optical Switches Overview Introduction This chapter provides information to assist you in maintaining a

Strona 127

3-2 Optical Switches 4000326 Rev A Section A Prisma Model 6474 Optical Switches Overview Introduction The information in this section applies to the

Strona 128

4000326 Rev A Optical Switches 3-3 Monitor Alarm Parameters Introduction From the ALARMS screen on the switch, you can determine whether there is a

Strona 129

3-4 Optical Switches 4000326 Rev A Monitor Alarm Parameters, Continued ALARMS Screen Description The ALARMS screens let you quickly determine the ca

Strona 130

4000326 Rev A Optical Switches 3-5 Monitor Alarm Parameters, Continued Monitoring Alarm Parameters The following table describes each alarm paramete

Strona 131

3-6 Optical Switches 4000326 Rev A Monitor Alarm Parameters, Continued Parameter Meaning Values Alarm Indicator HIGH: Above 16.50 V Illuminates

Strona 132

4000326 Rev A Optical Switches 3-7 Monitor Status Parameters Introduction From the STATUS screen on the switch, you can check various parameters to

Strona 133

3-8 Optical Switches 4000326 Rev A Monitor Status Parameters, Continued STATUS Screen Description The first STATUS screen is called the Summary STAT

Strona 134

4000326 Rev A Optical Switches 3-9 Monitor Status Parameters, Continued Monitoring Status Parameters The following table describes each status param

Strona 135

1-6 Transmitters 4000326 Rev A Monitor Alarm Parameters, Continued 6473-NC Overlay Transmitter 6473-10 750 MHz Transmitter 6473-12 750 MHz Transmi

Strona 136

3-10 Optical Switches 4000326 Rev A Monitor Status Parameters, Continued Parameter Meaning Values A5Vdc +5 V analog power level 0 V DC to +10.8

Strona 137

4000326 Rev A Optical Switches 3-11 General Troubleshooting Information Introduction The following information: • Lists the equipment you might nee

Strona 138

3-12 Optical Switches 4000326 Rev A Troubleshoot Alarm Conditions Introduction The information in this section provides possible solutions to the fo

Strona 139 - Receivers

4000326 Rev A Optical Switches 3-13 Troubleshoot Alarm Conditions, Continued Alarm Condition Status Possible Causes Possible Solutions The switch

Strona 140 - Section A

3-14 Optical Switches 4000326 Rev A Troubleshoot Alarm Conditions, Continued Troubleshooting Power Supply Alarms The following table shows the possi

Strona 141 - Monitor Alarm Parameters

4000326 Rev A Optical Switches 3-15 Troubleshoot Alarm Conditions, Continued Alarm Status Possible Causes Possible Solutions Backplane Power Sup

Strona 142

3-16 Optical Switches 4000326 Rev A Switch Maintenance Schedule Introduction Regular maintenance is required to extend the life of the switch and to

Strona 143

4000326 Rev A Optical Switches 3-17 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect

Strona 144 - Monitor Status Parameters

3-18 Optical Switches 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean

Strona 145

4000326 Rev A Optical Switches 3-19 Section B Prisma II Optical Switch Overview Introduction The information in this section applies to the Prisma I

Strona 146

4000326 Rev A Transmitters 1-7 Monitor Alarm Parameters, Continued Monitoring Alarm Parameters for Model 6473 870 MHz Forward Transmitters The follo

Strona 147

3-20 Optical Switches 4000326 Rev A Monitor Alarm Parameters Using the ICIM Introduction The Intelligent Communications Interface Module (ICIM) in t

Strona 148

4000326 Rev A Optical Switches 3-21 Monitor Alarm Parameters Using the ICIM, Continued Monitoring Alarm Parameters From the MAIN or SCROLL menus on

Strona 149

3-22 Optical Switches 4000326 Rev A Monitor Status Parameters Using the ICIM Introduction The STATUS menu on the ICIM allows you to verify the statu

Strona 150

4000326 Rev A Optical Switches 3-23 Monitor Status Parameters Using the ICIM, Continued Monitoring Status Parameters From the MAIN or SCROLL menus o

Strona 151

3-24 Optical Switches 4000326 Rev A Configure Parameters Using the ICIM Introduction The CONFIG menu on the ICIM allows you to configure several swi

Strona 152

4000326 Rev A Optical Switches 3-25 Configure Parameters Using the ICIM, Continued Parameter Description Values Default HystAmpl Hysteresis Amplit

Strona 153

3-26 Optical Switches 4000326 Rev A Monitor Alarm Parameters Using LCI Introduction The Local Craft Interface (LCI) software allows you to view alar

Strona 154

4000326 Rev A Optical Switches 3-27 Modify Alarm Limits Using LCI Introduction Using LCI, you can modify the nominal input power for both ports. M

Strona 155

3-28 Optical Switches 4000326 Rev A Monitor Status Parameters Using LCI Introduction The LCI software allows you to verify the status of the switch.

Strona 156 - Section B

4000326 Rev A Optical Switches 3-29 Monitor Status Parameters Using LCI, Continued Monitoring Status Parameters To monitor the parameters, navigate

Strona 157

1-8 Transmitters 4000326 Rev A Monitor Alarm Parameters, Continued 6473 870 MHz Transmitter 6473-10 870 MHz Transmitter Parameter Status Alarm Ind

Strona 158

3-30 Optical Switches 4000326 Rev A Configure Parameters Using LCI Introduction The LCI software allows you to configure several switch parameters.

Strona 159

4000326 Rev A Optical Switches 3-31 Configure Parameters Using LCI, Continued Parameter Description Values Default Hysteresis Amplitude Hysteresis

Strona 160

3-32 Optical Switches 4000326 Rev A General Troubleshooting Information Introduction The following information: • Lists the equipment you might nee

Strona 161 - Receiver Specifications

4000326 Rev A Optical Switches 3-33 Troubleshoot Alarm Conditions Introduction The following troubleshooting information helps identify possible cau

Strona 162

3-34 Optical Switches 4000326 Rev A Switch Maintenance Schedule Introduction Regular maintenance is required to extend the life of the switch and to

Strona 163

4000326 Rev A Optical Switches 3-35 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect

Strona 164

3-36 Optical Switches 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean

Strona 165

4000326 Rev A Optical Amplifiers 4-1 Chapter 4 Optical Amplifiers Overview Introduction This chapter provides information to assist you in maintaini

Strona 166

4-2 Optical Amplifiers 4000326 Rev A Section A Prisma Model 6476 EDFA Optical Amplifiers Overview Introduction The information in this section appli

Strona 167 - Section C

4000326 Rev A Optical Amplifiers 4-3 Monitor Alarm Parameters Introduction From the ALARMS screen on the amplifier, you can determine whether there

Strona 168

4000326 Rev A Transmitters 1-9 Monitor Status Parameters Introduction From the STATUS screen on the transmitter, you can check various parameters to

Strona 169

4-4 Optical Amplifiers 4000326 Rev A Monitor Alarm Parameters, Continued ALARMS Screen Description The ALARMS screens let you quickly determine the

Strona 170

4000326 Rev A Optical Amplifiers 4-5 Monitor Alarm Parameters, Continued Parameter Meaning Description -5Vdc -5 V DC analog power level The -5 V D

Strona 171

4-6 Optical Amplifiers 4000326 Rev A Monitor Status Parameters Introduction From the STATUS screen on the amplifier, you can check various parameter

Strona 172

4000326 Rev A Optical Amplifiers 4-7 Monitor Status Parameters, Continued STATUS Screen Description The first STATUS screen is called the Summary ST

Strona 173

4-8 Optical Amplifiers 4000326 Rev A Monitor Status Parameters, Continued Parameter Meaning Description Pump Pump status Status of the pump PSin

Strona 174

4000326 Rev A Optical Amplifiers 4-9 Amplifier Specifications Introduction The specifications listed in the following tables can be useful when trou

Strona 175

4-10 Optical Amplifiers 4000326 Rev A Amplifier Specifications, Continued Performance Characteristics Parameter Values Input power range 0.0 to 10

Strona 176

4000326 Rev A Optical Amplifiers 4-11 Amplifier Specifications, Continued Performance Characteristics Parameter Values Input power range 0.0 to 10

Strona 177

4-12 Optical Amplifiers 4000326 Rev A Amplifier Specifications, Continued Optical Characteristics Parameter Values Wavelength 1535–1565 nm Gain med

Strona 178

4000326 Rev A Optical Amplifiers 4-13 General Troubleshooting Information Introduction The following information: • Lists the equipment you might n

Strona 179

1-10 Transmitters 4000326 Rev A Monitor Status Parameters, Continued STATUS Screen Description The first STATUS screen is called the Summary STATUS

Strona 180

4-14 Optical Amplifiers 4000326 Rev A Troubleshoot Alarm Conditions Introduction The following troubleshooting information helps identify possible c

Strona 181 - Prisma II Forward Receiver

4000326 Rev A Optical Amplifiers 4-15 Troubleshoot Alarm Conditions, Continued Alarm Condition Possible Causes Possible Solutions Fiber path is b

Strona 182

4-16 Optical Amplifiers 4000326 Rev A Amplifier Maintenance Schedule Introduction Regular maintenance is required to extend the life of the amplifie

Strona 183

4000326 Rev A Optical Amplifiers 4-17 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconne

Strona 184

4-18 Optical Amplifiers 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clea

Strona 185

4000326 Rev A Optical Amplifiers 4-19 Section B Prisma Models 6476-22 and 6476-25 CLAD Optical Amplifiers Overview Introduction The information in t

Strona 186

4-20 Optical Amplifiers 4000326 Rev A Monitor Alarm Parameters Introduction From the ALARMS screen on the amplifier, you can determine whether there

Strona 187

4000326 Rev A Optical Amplifiers 4-21 Monitor Alarm Parameters, Continued ALARMS Screen Description The ALARMS screens let you quickly determine the

Strona 188

4-22 Optical Amplifiers 4000326 Rev A Monitor Alarm Parameters, Continued Parameter Meaning Description Mtemp Module temperature Temperature of th

Strona 189

4000326 Rev A Optical Amplifiers 4-23 Monitor Status Parameters Introduction From the STATUS screen on the amplifier, you can check various paramete

Strona 190 - Monitoring Status Parameters

4000326 Rev A Transmitters 1-11 Monitor Status Parameters, Continued Monitoring Status Parameters The following table describes each status paramete

Strona 191

4-24 Optical Amplifiers 4000326 Rev A Monitor Status Parameters, Continued STATUS Screen Description The STATUS menu on the ICIM allows you to verif

Strona 192

4000326 Rev A Optical Amplifiers 4-25 Monitor Status Parameters, Continued Parameter Meaning Description D5Vdc +5 V DC digital power level Status

Strona 193

4-26 Optical Amplifiers 4000326 Rev A Amplifier Specifications Introduction The specifications listed in the following tables can be useful when tro

Strona 194

4000326 Rev A Optical Amplifiers 4-27 Amplifier Specifications, Continued Optical Characteristics Parameter Values Wavelength 1535–1565 nm Output p

Strona 195

4-28 Optical Amplifiers 4000326 Rev A General Troubleshooting Information Introduction The following information: • Lists the equipment you might n

Strona 196

4000326 Rev A Optical Amplifiers 4-29 Troubleshoot Alarm Conditions Introduction The following troubleshooting information helps identify possible c

Strona 197 - Section E

4-30 Optical Amplifiers 4000326 Rev A Amplifier Maintenance Schedule Introduction Regular maintenance is required to extend the life of the amplifie

Strona 198

4000326 Rev A Optical Amplifiers 4-31 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconne

Strona 199

4-32 Optical Amplifiers 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clea

Strona 200

4000326 Rev A Optical Amplifiers 4-33 Section C Prisma II Optical Amplifiers Overview Introduction The information in this section applies to the fo

Strona 201

1-12 Transmitters 4000326 Rev A Monitor Status Parameters, Continued Parameter 6473-NC Overlay Transmitter 6473-10 750 MHz Transmitter 6473-12 750

Strona 202

4-34 Optical Amplifiers 4000326 Rev A Monitor Alarm Parameters Using the ICIM Introduction The Intelligent Communications Interface Module (ICIM) in

Strona 203

4000326 Rev A Optical Amplifiers 4-35 Monitor Alarm Parameters Using the ICIM, Continued Monitoring Alarm Parameters From the MAIN or SCROLL menus o

Strona 204

4-36 Optical Amplifiers 4000326 Rev A Monitor Status Parameters Using the ICIM Introduction The STATUS menu on the ICIM allows you to verify the sta

Strona 205

4000326 Rev A Optical Amplifiers 4-37 Monitor Status Parameters Using the ICIM, Continued Monitoring Status Parameters From the MAIN or SCROLL menus

Strona 206

4-38 Optical Amplifiers 4000326 Rev A Configure Parameters Using the ICIM Introduction The CONFIG menu on the ICIM allows you to configure several a

Strona 207

4000326 Rev A Optical Amplifiers 4-39 Monitor Alarm Parameters Using LCI Introduction The Local Craft Interface (LCI) software allows you to view al

Strona 208

4-40 Optical Amplifiers 4000326 Rev A Monitor Alarm Parameters Using LCI, Continued Monitoring Alarm Parameters To monitor the alarms, navigate to t

Strona 209

4000326 Rev A Optical Amplifiers 4-41 Modify Alarm Limits Using LCI Introduction Using LCI, you can modify limits for several alarm parameters for t

Strona 210

4-42 Optical Amplifiers 4000326 Rev A Monitor Status Parameters Using LCI Introduction The LCI software allows you to verify the status of the ampli

Strona 211 - Optical Switches

4000326 Rev A Optical Amplifiers 4-43 Monitor Status Parameters Using LCI, Continued Monitoring Status Parameters To monitor the parameters, navigat

Strona 212

4000326 Rev A Transmitters 1-13 General Troubleshooting Information Introduction The following information: • Lists the equipment you might need to

Strona 213

4-44 Optical Amplifiers 4000326 Rev A Configure Parameters Using LCI Introduction The LCI software allows you to configure several amplifier paramet

Strona 214

4000326 Rev A Optical Amplifiers 4-45 General Troubleshooting Information Introduction The following information: • Lists the equipment you might n

Strona 215

4-46 Optical Amplifiers 4000326 Rev A Troubleshoot Alarm Conditions Introduction The following troubleshooting information helps identify possible c

Strona 216

4000326 Rev A Optical Amplifiers 4-47 Amplifier Maintenance Schedule Introduction Regular maintenance is required to extend the life of the amplifie

Strona 217

4-48 Optical Amplifiers 4000326 Rev A Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconne

Strona 218

4000326 Rev A Optical Amplifiers 4-49 Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clea

Strona 220

4000326 Rev A Chassis 5-1 Chapter 5 Chassis Overview Introduction This chapter provides information to assist you in maintaining and troubleshooting

Strona 221

5-2 Chassis 4000326 Rev A Section A Prisma Model 6470-R2 Chassis Overview Introduction The information in this section applies to the Prisma Model 6

Strona 222

4000326 Rev A Chassis 5-3 Power Supply Specifications Introduction The Model 6471 Rack-Mount Power Supply provides primary and backup power for two

Strona 223

Prisma® and Prisma II™ Platform Maintenance and Troubleshooting

Strona 224

1-14 Transmitters 4000326 Rev A Test the Power and Communications Connector Introduction During troubleshooting, you may need to test the power and

Strona 225

5-4 Chassis 4000326 Rev A Power Supply Specifications, Continued Environmental Specifications Parameter Values Operating temperature range (ambient

Strona 226 - Switch Maintenance Schedule

4000326 Rev A Chassis 5-5 Power Supply Specifications, Continued Electrical Requirements Parameter Values Voltage requirements 3 x 48 V DC (42–56

Strona 227

5-6 Chassis 4000326 Rev A General Troubleshooting Information Introduction Because the main function of the chassis is to distribute power and estab

Strona 228

4000326 Rev A Chassis 5-7 Troubleshoot Alarm Conditions Introduction The information in this section provides possible solutions to alarm conditions

Strona 229 - Prisma II Optical Switch

5-8 Chassis 4000326 Rev A Chassis Maintenance Schedule Introduction Regular maintenance is required to extend the life of the chassis and to ensure

Strona 230 - Switch Alarm LED Description

4000326 Rev A Chassis 5-9 Section B Prisma II Chassis Overview Introduction The information in this section applies to the Prisma II Chassis. In Thi

Strona 231

5-10 Chassis 4000326 Rev A Monitor Alarm Parameters Using the ICIM Introduction The Intelligent Communications Interface Module (ICIM) in the Prisma

Strona 232

4000326 Rev A Chassis 5-11 Monitor Alarm Parameters Using the ICIM, Continued Monitoring Alarm Parameters From the MAIN or SCROLL menus on the ICIM,

Strona 233

5-12 Chassis 4000326 Rev A Monitor Status Parameters Using the ICIM Introduction The STATUS menu on the ICIM allows you to verify the status of the

Strona 234

4000326 Rev A Chassis 5-13 Monitor Status Parameters Using the ICIM, Continued Monitoring Status Parameters From the MAIN or SCROLL menus on the ICI

Strona 235

4000326 Rev A Transmitters 1-15 Test the Power and Communications Connector, Continued Connector Pin-Out Key Refer to the following illustration and

Strona 236 - Monitoring Alarm Parameters

5-14 Chassis 4000326 Rev A Monitor Alarm Parameters Using LCI Introduction The Local Craft Interface (LCI) software allows you to view alarms that m

Strona 237

4000326 Rev A Chassis 5-15 Monitor Alarm Parameters Using LCI, Continued Monitoring Alarm Parameters To monitor the alarms, navigate to the Module D

Strona 238

5-16 Chassis 4000326 Rev A Modify Alarm Limits Using LCI Introduction Using LCI, you can modify limits for several alarm parameters for the power su

Strona 239

4000326 Rev A Chassis 5-17 Monitor Status Parameters Using LCI Introduction The LCI software allows you to verify the status of the power supply and

Strona 240

5-18 Chassis 4000326 Rev A Monitor Status Parameters Using LCI, Continued Monitoring Status Parameters To monitor the parameters, navigate to the Mo

Strona 241

4000326 Rev A Chassis 5-19 General Troubleshooting Information Introduction Because the main function of the chassis is to distribute power and esta

Strona 242

5-20 Chassis 4000326 Rev A Troubleshoot Alarm Conditions Introduction The information in this section provides possible solutions to the following t

Strona 243

4000326 Rev A Chassis 5-21 Troubleshoot Alarm Conditions, Continued Troubleshooting Power Supply and Fan Tray Alarms The following table shows the p

Strona 244

5-22 Chassis 4000326 Rev A Chassis Maintenance Schedule Introduction Regular maintenance is required to extend the life of the chassis and to ensure

Strona 245

4000326 Rev A Chassis 5-23 Section C Prisma II High Density Chassis Overview Introduction The information in this section applies to the Prisma II H

Strona 246

1-16 Transmitters 4000326 Rev A Test the Power and Communications Connector, Continued Description Pin No. 6473-NC Overlay Transmitter 6473 870 MH

Strona 247 - Optical Amplifiers

5-24 Chassis 4000326 Rev A Monitor Alarm Parameters Using the ICIM Introduction The Intelligent Communications Interface Module (ICIM) in the Prisma

Strona 248

4000326 Rev A Chassis 5-25 Monitor Alarm Parameters Using the ICIM, Continued Monitoring Alarm Parameters From the MAIN or SCROLL menus on the ICIM,

Strona 249

5-26 Chassis 4000326 Rev A Monitor Status Parameters Using the ICIM Introduction The STATUS menu on the ICIM allows you to verify the status of the

Strona 250

4000326 Rev A Chassis 5-27 Monitor Status Parameters Using the ICIM, Continued Monitoring Status Parameters From the MAIN or SCROLL menus on the ICI

Strona 251

5-28 Chassis 4000326 Rev A Monitor Alarm Parameters Using LCI Introduction The Local Craft Interface (LCI) software allows you to view alarms that m

Strona 252

4000326 Rev A Chassis 5-29 Monitor Alarm Parameters Using LCI, Continued Monitoring Alarm Parameters To monitor the alarms, navigate to the Module D

Strona 253

5-30 Chassis 4000326 Rev A Modify Alarm Limits Using LCI Introduction Using LCI, you can modify limits for several alarm parameters for the power su

Strona 254

4000326 Rev A Chassis 5-31 Monitor Status Parameters Using LCI Introduction The LCI software allows you to verify the status of the power supply and

Strona 255 - Amplifier Specifications

5-32 Chassis 4000326 Rev A Monitor Status Parameters Using LCI, Continued Monitoring Status Parameters To monitor the parameters, navigate to the Mo

Strona 256

4000326 Rev A Chassis 5-33 General Troubleshooting Information Introduction The following information: • Lists the equipment you might need to trou

Strona 257

4000326 Rev A Transmitters 1-17 Test the Power and Communications Connector, Continued Description Pin No. 6473-NC Overlay Transmitter 6473 870 MH

Strona 258

5-34 Chassis 4000326 Rev A Troubleshoot Alarm Conditions Introduction The information in this section provides possible solutions to the following t

Strona 259

4000326 Rev A Chassis 5-35 Troubleshoot Alarm Conditions, Continued Troubleshooting Power Supply and Fan Tray Alarms The following table shows the p

Strona 260

5-36 Chassis 4000326 Rev A Chassis Maintenance Schedule Introduction Regular maintenance is required to extend the life of the chassis and to ensure

Strona 261

4000326 Rev A Customer Information 6-1 Chapter 6 Customer Information Overview Introduction This chapter contains information on obtaining product s

Strona 262

6-2 Customer Information 4000326 Rev A Product Support Obtaining Support IF you have… THEN… general questions about this product contact your dis

Strona 263

4000326 Rev A Customer Information 6-3 Returning Products Introduction Returning a product to Scientific-Atlanta for repair includes the following s

Strona 264

6-4 Customer Information 4000326 Rev A Returning Products, Continued 4. Telephone SciCare Broadband Services to request an RMA number. Are you lo

Strona 265 - CLAD Optical Amplifiers

4000326 Rev A Customer Information 6-5 Returning Products, Continued Packing and Shipping the Product Follow these steps to pack the product and shi

Strona 268

1-18 Transmitters 4000326 Rev A Troubleshoot Alarm Conditions Introduction The following tables provide information about transmitter and power supp

Strona 269

Want MORE? www.scientificatlanta.com Now TTAALLKK to someone United States Scien

Strona 270

4000326 Rev A Transmitters 1-19 Troubleshoot Alarm Conditions, Continued Alarm Status Possible Causes Possible Solutions RF level High or Low R

Strona 271

1-20 Transmitters 4000326 Rev A Troubleshoot Alarm Conditions, Continued Troubleshooting Power Supply Alarms The following table shows the possible

Strona 272

4000326 Rev A Transmitters 1-21 Transmitter Maintenance Schedule Introduction Regular maintenance is required to extend the life of the transmitter

Strona 273

1-22 Transmitters 4000326 Rev A Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect pro

Strona 274

4000326 Rev A Transmitters 1-23 Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean a fi

Strona 275

Notices Trademark Acknowledgments • “Bringing the Interactive Experience Home”, Prisma II, and SciCare are trademarks of Scientific-Atlanta Inc. • S

Strona 276

1-24 Transmitters 4000326 Rev A Section B Prisma Model 6473-R Reverse Transmitter Overview Introduction The information in this section applies to t

Strona 277

4000326 Rev A Transmitters 1-25 Monitor Alarm Parameters Introduction From the ALARMS screen on the transmitter, you can determine whether there is

Strona 278

1-26 Transmitters 4000326 Rev A Monitor Alarm Parameters, Continued ALARMS Screen Description The ALARMS screens let you quickly determine the cause

Strona 279 - Prisma II Optical Amplifiers

4000326 Rev A Transmitters 1-27 Monitor Alarm Parameters, Continued Monitoring Alarm Parameters The following table describes each alarm parameter.

Strona 280

1-28 Transmitters 4000326 Rev A Monitor Status Parameters Introduction From the STATUS screen on the transmitter, you can check various parameters t

Strona 281

4000326 Rev A Transmitters 1-29 Monitor Status Parameters, Continued STATUS Screen Description The first STATUS screen is called the Summary STATUS

Strona 282

1-30 Transmitters 4000326 Rev A Monitor Status Parameters, Continued Monitoring Status Parameters The following table describes each status paramete

Strona 283

4000326 Rev A Transmitters 1-31 General Troubleshooting Information Introduction The following information: • Lists the equipment you might need to

Strona 284

1-32 Transmitters 4000326 Rev A Troubleshoot Alarm Conditions Introduction The following tables provide information about transmitter and power supp

Strona 285

4000326 Rev A Transmitters 1-33 Troubleshoot Alarm Conditions, Continued Alarm Status Possible Causes Possible Solutions RF level High or Low R

Strona 286

Contents 4000326 Rev A iii Safety Precautions...

Strona 287

1-34 Transmitters 4000326 Rev A Troubleshoot Alarm Conditions, Continued Troubleshooting Power Supply Alarms The following table shows the possible

Strona 288

4000326 Rev A Transmitters 1-35 Troubleshoot Alarm Conditions, Continued Alarm Status Possible Causes Possible Solutions Backplane power supply

Strona 289

1-36 Transmitters 4000326 Rev A Transmitter Maintenance Schedule Introduction Regular maintenance is required to extend the life of the transmitter

Strona 290

4000326 Rev A Transmitters 1-37 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect pro

Strona 291

1-38 Transmitters 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean a fi

Strona 292

4000326 Rev A Transmitters 1-39 Section C Prisma Model 6475 Transmitters Overview Introduction The information in this section applies to the follow

Strona 293

1-40 Transmitters 4000326 Rev A Monitor Alarm Parameters Introduction From the ALARMS screen on the transmitter, you can determine whether there is

Strona 294

4000326 Rev A Transmitters 1-41 Monitor Alarm Parameters, Continued ALARMS Screen Description The ALARMS screens let you quickly determine the cause

Strona 295

1-42 Transmitters 4000326 Rev A Monitor Alarm Parameters, Continued Parameter Meaning Description Lock2 PLL lock status The PLL lock status for S

Strona 296

4000326 Rev A Transmitters 1-43 Monitor Status Parameters Introduction From the STATUS screen on the transmitter, you can check various parameters t

Strona 297 - Chassis

Contents, Continued iv 4000326 Rev A Section D Prisma II Targeted Service Delivery Transmitter Overview...

Strona 298 - Prisma Model 6470-R2 Chassis

1-44 Transmitters 4000326 Rev A Monitor Status Parameters, Continued STATUS Screen Description The first STATUS screen is called the Summary STATUS

Strona 299 - Power Supply Specifications

4000326 Rev A Transmitters 1-45 Monitor Status Parameters, Continued Parameter Meaning Description D5Vdc +5 V DC digital +5 V DC supply for digi

Strona 300

1-46 Transmitters 4000326 Rev A Transmitter Specifications Introduction The specifications listed in the following tables can be useful when trouble

Strona 301

4000326 Rev A Transmitters 1-47 Transmitter Specifications, Continued RF Electrical Characteristics Parameter Values RF input levels + 24.0 dBm V/

Strona 302

1-48 Transmitters 4000326 Rev A Transmitter Specifications, Continued Model 6475L EMT 1550 nm Externally Modulated Transmitter Power Requirements P

Strona 303 - Troubleshooting Alarm Alarms

4000326 Rev A Transmitters 1-49 Transmitter Specifications, Continued RF Input Levels Note: 0.0 dBm V is equivalent to the power associated with 1

Strona 304 - Chassis Maintenance Schedule

1-50 Transmitters 4000326 Rev A Transmitter Specifications, Continued Model 6475Q 1550 nm Forward Transmitter Power Requirements Parameter Values P

Strona 305 - Prisma II Chassis

4000326 Rev A Transmitters 1-51 Transmitter Specifications, Continued RF Electrical Characteristics Parameter Values Channel loading 16 NTSC RF dr

Strona 306 - Alarm LED Descriptions

1-52 Transmitters 4000326 Rev A Transmitter Specifications, Continued Model 6475R ITU 1550 nm Externally Modulated Transmitter Power Requirements P

Strona 307

4000326 Rev A Transmitters 1-53 Transmitter Specifications, Continued RF Electrical Characteristics Parameter Values RF drive levels -40.0 to –56.

Strona 308

Contents, Continued 4000326 Rev A v Section G Prisma II 1550 nm Transmitters Overview...

Strona 309

1-54 Transmitters 4000326 Rev A Transmitter Specifications, Continued Model 6475S ITU 1550 nm Externally Modulated Transmitter Power Requirements P

Strona 310

4000326 Rev A Transmitters 1-55 Transmitter Specifications, Continued RF Electrical Specifications Parameter Values RF input levels +22 ± 3 dBm V/

Strona 311

1-56 Transmitters 4000326 Rev A General Troubleshooting Information Introduction The following information: • Lists the equipment you might need to

Strona 312

4000326 Rev A Transmitters 1-57 Troubleshoot Alarm Conditions Introduction The following troubleshooting information helps identify possible causes

Strona 313

1-58 Transmitters 4000326 Rev A Transmitter Maintenance Schedule Introduction Regular maintenance is required to extend the life of the transmitter

Strona 314

4000326 Rev A Transmitters 1-59 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect pro

Strona 315

1-60 Transmitters 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean a fi

Strona 316

4000326 Rev A Transmitters 1-61 Section D Prisma II Targeted Service Delivery Transmitter Overview Introduction The information in this section appl

Strona 317

1-62 Transmitters 4000326 Rev A Monitor Alarm Parameters Using the ICIM Introduction The Intelligent Communications Interface Module (ICIM) in the P

Strona 318

4000326 Rev A Transmitters 1-63 Monitor Alarm Parameters Using the ICIM, Continued Monitoring Transmitter Alarm Parameters From the MAIN or SCROLL m

Strona 319

Contents, Continued vi 4000326 Rev A Section C Prisma Model 6971-DR Dual Reverse Receiver Overview...

Strona 320

1-64 Transmitters 4000326 Rev A General Troubleshooting Information Introduction Because the main function of the chassis is to distribute power and

Strona 321

4000326 Rev A Transmitters 1-65 Troubleshoot Alarm Conditions Introduction The information in this section provides possible solutions to transmitte

Strona 322

1-66 Transmitters 4000326 Rev A Transmitter Maintenance Schedule Introduction Regular maintenance is required to extend the life of the transmitter

Strona 323

4000326 Rev A Transmitters 1-67 Fiber Optic Connector Cleaning Procedure Introduction Clean fiber optic connectors can help prevent interconnect pro

Strona 324

1-68 Transmitters 4000326 Rev A Fiber Optic Connector Cleaning Procedure, Continued Cleaning Fiber Optic Connectors Follow these steps to clean a fi

Strona 325

4000326 Rev A Transmitters 1-69 Section E Prisma II 1310 nm Forward Transmitter Overview Introduction The information in this section applies to the

Strona 326

1-70 Transmitters 4000326 Rev A Monitor Alarm Parameters Using the ICIM Introduction The Intelligent Communications Interface Module (ICIM) in the P

Strona 327

4000326 Rev A Transmitters 1-71 Monitor Alarm Parameters Using the ICIM, Continued Monitoring Alarm Parameters From the MAIN or SCROLL menus on the

Strona 328

1-72 Transmitters 4000326 Rev A Monitor Status Parameters Using the ICIM Introduction The STATUS menu on the ICIM allows you to verify the status of

Strona 329

4000326 Rev A Transmitters 1-73 Monitor Status Parameters Using the ICIM, Continued Monitoring Status Parameters From the MAIN or SCROLL menus on th

Strona 330

Contents, Continued 4000326 Rev A vii Chapter 3 Optical Switches Overview...

Strona 331

1-74 Transmitters 4000326 Rev A Configure Parameters Using the ICIM Introduction The CONFIG menu on the ICIM allows you to configure several transmi

Strona 332

4000326 Rev A Transmitters 1-75 Monitor Alarm Parameters Using LCI Introduction The Local Craft Interface (LCI) software allows you to view alarms t

Strona 333 - Customer Information

1-76 Transmitters 4000326 Rev A Monitor Alarm Parameters Using LCI, Continued Monitoring Alarm Parameters To monitor the alarms, navigate to the Mod

Strona 334 - Product Support

4000326 Rev A Transmitters 1-77 Modify Alarm Limits Using LCI Introduction Using LCI, you can modify limits for several alarm parameters for the tra

Strona 335 - Returning Products

1-78 Transmitters 4000326 Rev A Monitor Status Parameters Using LCI Introduction The LCI software allows you to verify the status of the transmitter

Strona 336

4000326 Rev A Transmitters 1-79 Monitor Status Parameters Using LCI, Continued Monitoring Status Parameters To monitor the parameters, navigate to t

Strona 337

1-80 Transmitters 4000326 Rev A Configure Parameters Using LCI Introduction The LCI software allows you to configure several transmitter parameters.

Strona 338

4000326 Rev A Transmitters 1-81 General Troubleshooting Information Introduction The following information: • Lists the equipment you might need to

Strona 339

1-82 Transmitters 4000326 Rev A Troubleshoot Alarm Conditions Introduction The following troubleshooting information helps identify possible causes

Strona 340 - DOCUMENT

4000326 Rev A Transmitters 1-83 Transmitter Maintenance Schedule Introduction Regular maintenance is required to extend the life of the transmitter

Komentarze do niniejszej Instrukcji